Product description
3.3
Examples of range of use
The C4000 Select safety light curtain operates correctly as a protective device only if the
following conditions are met:
The control of the machine must be electrical.
The dangerous state of the machine must be transferable at any time into a safe state.
Sender and receiver unit must be mounted so that objects penetrating the hazardous
area are safely identified by the C4000 Select.
An external reset/restart function (e.g. button) must be fitted outside the hazardous
area such that it cannot be operated by a person working inside the hazardous area.
When operating the reset button, the operator must have full visual command of the
hazardous area.
The statutory and local rules and regulations must be observed when installing and
using the device.
Fig. 6: Hazardous point pro-
tection using a C4000 Select
safety light curtain
(left)
Fig. 7: Hazardous area pro-
tection using a C4000 Select
safety light curtain
(right)
Fig. 8: Access protection
using a C4000 Select safety
light curtain cascaded with
an S3000 safety laser
scanner