Chapter
6
Operating Instructions
CLV65x Bar Code Scanner
62
©
SICK AG · Division Auto Ident · Germany · All rights reserved
8011980/0000/2009-04-21
Electrical installation
6.4.5
Wiring switching inputs
If the bar code scanner's reading process should be triggered by an external sensor, the rea-
ding pulse sensor is connected to the "
Sensor 1
" switching input.
Fig. 6-6:
Wiring the “Sensor 1“ switching input on the 15-pole D-Sub-HD plug
The "
Sensor 2
" switching input has the following functions, among others:
Trigger source for
•
Incremental encoder input
•
Reading pulse generator for reading pulse end
Fig. 6-7:
Wiring the “Sensor 2“ switching input on the 15-pole D-Sub-HD plug
Important
The ratings for "Sensor 1" and "Sensor 2" are identical.
Tab. 6-7:
Ratings for the switching inputs
Connect switching inputs depending on application.
Switching behaviour
Power fed to the input opens the internal reading gate of the bar code
scanner.
(Default setting: active high; debouncing: max. 30 ms (standard))
Features
– Optodecoupled, reverse polarity protected
– Can be wired with the PNP output of a sensor
Electrical values
Low: |V
in
|
≤
2 V; |I
in
|
≤
0.3 mA
High: 6 V
≤
|V
in
|
≤
32 V; 0.7 mA
≤
|I
in
|
≤
5.0 mA