Attribute ID
Function
Detailed descrip‐
tion
Access
Data type
Content/meaning
0x70
Response speed
R/W
UINT
0: 16 us
1: 70 us
2: 250 us
3: 2 ms
4: 8 ms
0x71
Sender strength
R/W
UINT
0: low strength
1: medium strength
2: normal
0x72
MF input
R/W
UINT
0: External teach-in
1: Test input
2: Synchronization
3: Reset counter
4: Master teach-in
5: No function
0x73
Key lock
R/W
UINT
0: cancel
1: Completely locked
2: Locked, but external teach-in
available
0x74
Operating mode
CH1
R/W
UINT
0: Light on
1: Dark on
0x75
CH2
R/W
UINT
0x76
Threshold
CH1 Lower limit
R/W
UINT
-999 ... 9,999 All values outside the
range
will be replaced by the nearest valid
values.
0x77
CH1 Upper limit
R/W
UINT
0x78
CH2 Lower limit
R/W
UINT
0x79
CH2 Upper limit
R/W
UINT
0x7A
Counter setting
CH1
R/W
UINT
0: Delay off
1: Single pulse
0x7B
CH2
R/W
UINT
0x7C
Delay time off
CH1
R/W
UINT
0 ... 9,999: 0 ... 9,999 ms
-1 … -9: 0.1 ... 0.9 ms
0x7D
Delay time on
CH1
R/W
UINT
0x7E
Delay time off
CH2
R/W
UINT
0x7F
Delay time on
CH2
R/W
UINT
0x83
Hysteresis
R/W
UINT
1 ... 40
0x85
ASC (automated switch‐
ing threshold adjust‐
ment)
R/W
UINT
0: Off
1: Normal
0x86
Eco Mode
R/W
UINT
0: Off
1: Display in energy-saving mode
0x87
Reverse display
R/W
UINT
0: Normal
1: Display reversed
0xD0
Save zero reset
R/W
UINT
Write any value to clear
zero reset
0xD1
Cancel zero reset
R/W
UINT
Write any value to clear
zero reset
0xD2
Teach-in 1-point
R/W
UINT
1: CH1 2: CH2
0xD3
Teach in 2-point
R/W
UINT
1: CH1 2: CH2
0xD4
Reset
R/W
UINT
3: Execute
0xDB
Return to start menu
R/W
UINT
Write any value to return to start
menu
0xDC
Reset to factory set‐
tings
R/W
UINT
3: Execute
OPERATION
7
8024950/2019-11-04 | SICK
O P E R A T I N G I N S T R U C T I O N S | WI180C-EN
29
Subject to change without notice