Attribute ID
Function
Access
Data type
Content/meaning
0x03
Q3 of all modules
R
UINT
Output state of third output or external
input of all modules (every bit 0 = Off, 1 =
On)
0x05
Error status of all mod‐
ules
R
UINT
(each Bit 0 = off, 1 = on)
0x06
Teach of all modules
R/W
UINT
The attribute permits teach-in of the
switching point(s) of all modules. The first
switching point is taught at the change
from 0 to 1 Bit (or the teach-in process is
started in the case of dynamic teach-in).
The second switching point is taught at the
change from 1 to 0 Bit (or the teach-in
process is ended in the case of dynamic
teach-in).
0x07
Error confirmation of all
modules
R/W
UINT
(every bit 0 = No action, 1 = Acknowledge
error).
0x08
Product series
R
UINT
Bit 15 ... 12 = Manufacturer (1 = SICK)
Bit 1 ... 8 = Categories (5 = Communica‐
tion unit)
Bit 7 .. .0 = Family (9 = WI180C-EN)
0x09
Product type
R
UINT
1 = WI180C-EN
0x0A
firmware version
R
UINT
0x0B
Protocol version
R
UINT
1
0x0C
Product version
R
UINT
1
0x0D
Vendor name
R
STRG(7)
“SICK AG”
0x0E
Product name
R
STRG(9)
“WI180C-EN”
0x0F
Product ID
R
STRG(7)
"6068090"
0x10
User ID
R/W
STRG(32)
max. 32 characters
0x11
Operating status
R
UINT
0 = Initialization, 2 = Execution
0x12
Manufacturer ID
R
UINT
0x0328
0x13
Network profile
R
STRG(19)
"Ethernet/IP Coupler"
0x67
Serial number
R
STRG(11)
0x68
Number of modules
present
R
UINT
0 ... 16
0x6A
Last error code
R/W
UINT
Reset via any write access
0xD0
Firmware identifier
application
R
STRG(4)
0xD1
Firmware identifier
communication
R
STRG(12)
0xD2
Find me
R/W
UINT
0 = Stop, 1 = Initialization
0xD3
Global diagnosis
R/W
UINT
0 = Off, 1 = On
0xDC
Reset to factory set‐
tings
W
UINT
3: Execute
7.8.2
Class 101 WLL180T
Table 33: Class services of class 101
Service code
Service
Description
0Eh
Get_Attribute_Single
Returns the values of an attribute
OPERATION
7
8024950/2019-11-04 | SICK