CONFIGURATION AND OPERATION
Example of configuration with two adjoining alarm area
Example of configuration with two scattered alarm area
17. Click each of the red areas individually to set the values for the alarm area. The
values defined are relative to the sensor position.
The coordinate fields are color-coded according to the values entered:
Color
Description
–
The values entered are within the possible parameter range.
Orange
One or more of the values are outside the reliable detection area (e.g., in
the close-up range with "Near detection" deactivated).
Red
One or more of the values are outside the detection area that is physical-
ly possible.
NOTE!
If a zone with intersecting vertices is defined, this alarm area is displayed in purple and
there won't be any alarm output.
18. Click the red cross in the top right-hand corner
to complete the configuration
process when the green symbol appears to indicate that the configuration is cor
-
rect
. During this process, pay attention to the basic parameters specified in the
technical data, such as height, distance, and so on
19. Enter
EXIT
in the command line to restart the system and switch to "Operator
mode".