Move
Move
MR
PW
R
MR
PW
R
s si
MR
PW
R
s
MR
PW
R
f
MR
PW
R
f
f
Regular Operation
Teach Menu
Enter Teach
Menu
2x
ca.
0.5 sec
(short)
1x
ca.
0.5 sec
(short)
Finish Teach
→ Save changes
→ MR-LED lights up
continuously as long as
magnet is within
measuring range
1x
ca.
1.5 sec
(long)
Start
Manual
Teach*
1x
ca.
0.5 sec
(short)
Switch to 10V end position teach
without setting 0V end position
1x
ca.
0.5 sec
(short)
Leave Menu
1x
ca.
0.5 sec
(short)
Leave Menu
Move pistonto 1st
end position (0V)
(default setting:
-25 mm)
Confirm 0V
end position and
leave Manual Teach
Move pistonto 2nd
end position (10V)
(default setting:
+25 mm)
1x
ca.
1.5 sec
(long)
1x
ca.
1.5 sec
(long)
1st end position
2nd end position
Confirm 10V
end position and
leave Manual Teach
No end position found?
→ Exit teach menu
without changes
Manual Teach
8
OPERATION
24
O P E R A T I N G I N S T R U C T I O N S | MPS-G with analog output
8025941/2020-07-16 | SICK
Subject to change without notice