6.2
Connections
6.2.1
Pin assignment/Connection d wire colors
MPS-GxxxxxxxAxxxxxxxxxxxxxxxxx: Open cable end
Table 3: Pin assignment for male connector, M8, A-coded, 4-pin
PIN
Connection
Pin assignment
1
BN
+ (L+)
2
WH
U
3
BU
- (M)
4
BK
-
0.08 mm
2
AWG 26
MPS-GxxxxxxxCxxxxxxxxxxxxxxxxx / MPS-GxxxxxxxDxxxxxxxxxxxxxxxxx: M8 connection
Table 4: Pin assignment for male connector, M8, A-coded, 4-pin
PIN
Connection
Pin assignment
1
BN
+ (L+)
2
WH
U
3
BU
- (M)
4
BK
-
2
1
4
3
MPS-GxxxxxxxExxxxxxxxxxxxxxxxx: M12 connection
Table 5: Pin assignment for male connector, M12, A-coded, 4-pin
PIN
Connection
Pin assignment
1
BN
+ (L+)
2
WH
U
3
BU
- (M)
4
BK
-
1
2
3
4
6.3
Connecting the supply voltage
The sensor must be connected to a voltage supply with the following properties:
•
Supply voltage DC 12 V ... 30 V, with switched-on
Out-of-Range
display 13 V ... 30 V
(SELV/PELV as per currently valid standards)
•
Electricity source with at least 5 W power
ELECTRICAL INSTALLATION
6
8025941/2020-07-16 | SICK
O P E R A T I N G I N S T R U C T I O N S | MPS-G with analog output
17
Subject to change without notice