background image

EN 

Dear valued Customer,

thank you for choosing SYNCRA SILENT, a pump ideal to be used for marine 

and fresh water aquariums, decorative fountains, protein skimmers and water-

cooling systems. With its modern design, small dimensions, powerfull  and 

silence perfomances ,SYNCRA Line offers the best choice in the pumps market. SYNCRA 

pumps can be used fully submersed or  in inline applications and come with two stepped 

hoses included. It is easy to use and to maintain thanks to the complete absence of screws. 

Please, read carefully and save the following instructions to use in the best way your 

SYNCRA pump.

SAFETY INSTRUCTIONS:

SYNCRA is in conformity with the national and international security laws.

1)  Always isolate the pump from the mains electricity before installing or carrying out any 

maintenance. Power to the pump must be supplied through a Residual Current Device 

(RCD) with a rated residual operating current not exceeding 30mA.

2)  The pump can work “Wet & Dry”, in or out of water.

3)  Before connecting the pump to the electricity supply, check there are any damages on 

cord or plug.

4)  The pump has a type Z cable link. The cable and the plug cannot be substituted or 

repaired; in case of damage of them replace the entire pump.

5) 

ATTENTION:

 do not operate any appliance if it has a damaged cord or plug, if it is 

malfunctioning, or if it has been dropped or damaged in any way.

6)  The pump must not work without water to avoid damages to the motor.

7)  The pump can be used in liquids or in environment with a temperature not higher than 

35° C / 95° F.

8)  Do not use the pump for uses different to those for which it has been projected as, i.e. 

in bathroom or similar applications.

9)  Avoid to use the pump with corrosive and abrasive liquids.

10) The pump cannot be used by people with handicaps or by children if they are not 

supervised by a person responsible for their safety.

11) To avoid that accidental drips wet the plug or the socket, make a loop with the cord 

under the socket level 

(Fig. A)

.

12) Avoid to take the pump by the cord during the installation or maintenance.

13) The pump can be used only in the above mentioned applications and it is only for 

internal use.

14) If the pump or the filter is supplied with a cable 10 metres long, or a cable more than 6 

feet long for the American type (USA), these appliances are intended for outdoor use as 

required by international standards.

USE AND MAINTENANCE INSTRUCTIONS

The multifunctional pumps SYNCRA are made by the following components 

(Fig. 2)

:

PUMP INSTALLATION: USE AND REGULATION

Proceed as follow to install the pump:

Insert the suction cups in the holes under the pump body 

(5+1)

; clean the basin, fountain or 

aquarium wall and pressing the pump on the suction cups to fix it. Turn the water flow regulator 

on the front side of the pump to change the flow 

(3)

. SYNCRA is provided with 2 threaded 

adaptor 

(7)

 to which can be attached either flexible or rigid tubes suitable to adapt the pump 

for many uses. In case of “dry” use (out of water), take away the intake grill 

(9)

. Position the 

flow regulator according to the graining and detach it 

(3)

 pushing it softly out of its place. 

Screw the 2 adaptors in the inlet and outlet holes and connect the tubes. Insert the plug 

in the socket.

MAINTENANCE

For the periodic maintenance of the pump, first of all unplug the plug from the electric socket 

and then take the pump.

Proceed in the following way: take away the pre-filter 

(8)

, the ring nut 

(9)

 and then the 

threaded pre-chamber 

(4)

; take away the rotor 

(2)

 and rinse it under fresh water. Always 

check the condition of the o-rings.

Any damage to the o-rings, even small, can seriously endanger the pump performances. In 

this case it is recommended to substitute them.

Rinse each part with water, using a soft brush to remove the deposit. Then assemble 

everything in the inverse order.

ONLINE HELP

Watch  our  tutorial  videos  on  THE  SICCE  YOU  TUBE  official  channel  www.

youtube.com/SICCEspa.

INSTRUCTIONS FOR THE CORRECT DISCHARGE OF THE PRODUCT 

ACCORDING TO EU DIRECTIVE 2002/96/EC

When used or broken, the product does not have to be discharged with the 

other waste. It can be delivered to the specific electric waste collection centers 

or to dealers who give this service. Discharge separately an electric tool avoid 

negative consequences for the environment and for the Health and allows to regenerate the 

materials so to have a great saving of energy and resources.

WARRANTY

This product is guaranteed against defects of materials and workmanship for a period of 

3 years

 from the date of purchase, except the 

rotor 2

. The warranty certificate must be 

filled in by the dealer and must accompany the pump if it is returned for repair, along with 

the cash register receipt or similar document. The warranty covers the replacement of the 

defective parts. In case of improper use, tampering or negligence by the buyer or user, the 

guarantee is void and expires immediately. The guarantee is also void in absence of the 

cash register receipt or similar document. The shipping cost to and from the factory, or the 

repair station, have to be paid by the buyer.

FIND OUT HOW TO GET YOUR PRODUCT GUARANTEED FOR 5 YEARS

To improve our service and our clients’ satisfaction, SICCE offers the possibility of adding a 

years extension

 to the warranty by simply registering your product on our website www.sicce.

com in “Sicce for you/Product registration”. Fill-in the form and upload the product’s purchase 

receipt. After having correctly inserted all your data, complete the warranty extension request.

ATTENTION!

The limestone deposits and the natural wear-out of the components might cause a raise 

of the pump’s noise. However, they do not affect the good functioning of the pump. In this 

case, we recommend you to replace the impeller.

1

. Motor body completely submersible and insulated by epoxy resin

2

. Impeller assembly wear-resistant and noise-proof

    (ceramic shaft from mod. 2.0/2.5/3.0/3.5/4.0/5.0)

3

. Water flow regulator from min. (-) to max. (+) assembled to the pre-chamber

4

. Threaded pre-chamber (½” Gas mod.0.5/1.5/2.0;

    ¾” Gas mod. 2.0/2.5/3.0; 1” Gas mod. 3.5/4.0/5.0)

5

. Suction cups

6

. Pump back cover

7

. Threaded adaptors

8. Pre-filter

9. Intake grill

Summary of Contents for Syncra Silent 0.5

Page 1: ...SyncraSILENT Instruction manual 0 5 1 0 1 5 2 0 2 5 3 5 4 0 5 0 EN DE FR I ES NL PT RU...

Page 2: ...UK ONLY 10m cable no plug IMPORTANT The wires in this lead are coloured as follows Blue Neutral Brown Live The colours of the wires of the main lead of this appliance may not correspond with the colou...

Page 3: ...A Syncra Silent 0 5 1 0 1 5 2 0 2 5 3 0 3 5 4 0 5 0 230V 50 Hz Max flow rate 700 l h 950 l h 1 350 l h 2 150 l h 2 400 l h 2 700 l h 2 500 l h 3 500 l h 5 000 l h Watt 8 W 16 W 23 W 32 W 40 W 45 W 65...

Page 4: ...it de base doivent tre observ es y compris les suivantes LIRE ET OBSERVER TOUTES LES CONSIGNES DE S CURIT DANGER Pour viter tout choc lectrique une grande prudence est de rigueur d s que l eau est imp...

Page 5: ...of water take away the intake grill 9 Position the flow regulator according to the graining and detach it 3 pushing it softly out of its place Screw the 2 adaptors in the inlet and outlet holes and co...

Page 6: ...Hilfe des mit dem Ger t gelieferten Adapter biegsame Rohren Durchmesser angeschlossen werden F r das Betrieb au erhalb des Wasser entfernen Sie den Flussregler 3 Schlie en Sie die Adapter und Vorkamm...

Page 7: ...de deux raccords avec deux diam tres diff rents 7 Il est possible ainsi de connecter des tuyaux rigides ou souples afin de permettre une adaptation de la pompe toutes les applications n cessaires Pour...

Page 8: ...utti i possibili impieghi Nell uso fuori dell acqua togliere la ghiera e posizionando i dentini in corrispondenza della zigrinatura premendo leggermente togliere il regolatore di portata 3 e riposizio...

Page 9: ...ca el racor roscado del lado de la aspiraci n Atornillar los dos conectores y conectar los tubos respectivos Conectar a la red el ctrica MANUTENCI N Atenci n antes de cualquier intervenci n de manuten...

Page 10: ...er de voorkamer incl stromingsregelaar 3 en plaats de tandjes in de passende positie alvorens dit gedeelte uit de pomp te nemen Schroef de twee verbindingen voor zuig en persleiding aan de pomp en ver...

Page 11: ...xo 3 A SYNCRA vem com 2 adaptadores com rosca 7 em que podem ser ligados tanto tubos r gidos quanto flex veis que sirvam para adaptar a bomba para diversos usos Em caso de uso em seco fora da gua reti...

Page 12: ...SYNCRA SYNCRA t SYNCRA SYNCRA 1 30 mA 2 IN LINE 3 4 Z 5 6 7 35 C 95 F 8 9 10 11 A 12 5 1 3 SYN CRA 2 7 9 3 2 8 9 4 2 THE SICCE YOUTUBE www youtube com SICCEspa 2002 96 EC 2 3 5 SICCE 2 www sicce com S...

Page 13: ...115 36050 Pozzoleone VI Italy Tel 39 0444 462826 Fax 39 0444 462828 P IVA VAT 02883090249 info_service sicce com www sicce com SICCE USA 1737 Louisville Drive Knoxville Tennessee 37921 USA Ph 1 865 29...

Reviews: