background image

Electrical installation

The power supply must meet the specifications on the product.

The pump is intended to be used with either a weatherproof 
cable connector or permanently connected to the fixed wiring 
in the main system other than by means of a plug and socket.

The cores in the supply cable are coloured in accordance with the following
code:  

Brown = Live, Blue = Neutral, Green/Yellow = Earth.

The electric cable is permanently connected and sealed in the motor body.
If the supply cable is damaged the pump must not be used.

Do not use the supply cable to lift the pump as this may cause damage. 

WARNING - THIS PUMP MUST BE EARTHED

A Residual Current Device (RCD), also know as the Residual 
Current Circuit Breaker (RCCB), with a tripping current not 
exceeding 30mA must be installed in the supply circuit.

A means of disconnection from the supply having a contact separation
of at least 3mm in all poles must be incorporated in the fixed wiring.

INSTALLATION

For permanent installations to the mains supply, it is necessary to conform to
the regulations of the local electricity authority and this would include the use
of a metal or plastic conduit to protect the cable.

Attention has been drawn to the fact that special rules may exist concerning
the installation of your pond pump (i.e. local building regulations).

These pumps must not be used in swimming pools, or areas where people are
in contact with the water.

Always disconnect the mains electricity supply whilst the equipment is being
installed, repaired, maintained or handled.  Consult a qualified electrician if in
any doubt about wiring this product to the main supply.

Warning -

The Hydratech Multi pump is provided with a 

thermal cut out that temporarily switches off the pump in case 
of overheating and the pump may automatically restart.

6

7

Pump performance / flow chart

Technical Specification and Performance

GETTING TO KNOW YOUR HYDRATECH MULTI PUMP

CC

_

CC

_

CC

_

CC

_

CC

_

CC

_

HYDRATECH MULTI

800

1500

2500

3250

4000

6000

Cable Fitted

10m

10m

10m

10m

10m

10m

Voltage

230V

230V

230V

230V

230V

230V

Hertz

50Hz

50Hz

50Hz

50Hz

50Hz

50Hz

Watts

13

36

40

42

46

89

Safety Rating

IP68

IP68

IP68

IP68

IP68

IP68

Maximum Flow

790 

ltr/hr

1550 

ltr/hr

2750 

ltr/hr

3350 

ltr/hr

3800 

ltr/hr

5850 

ltr/hr

174 

gal/hr

341 

gal/hr

606 

gal/hr

737 

gal/hr

837 

gal/hr

1287 

gal/hr

Maximum Lift

1.25m

2.3m

3m

2.75m

3m

3.7m

4’1”

7’5”

9’8”

9’2”

9’8”

12’1”

Multi Instructions 3250 AW  23/3/06  10:23 am  Page 9

Summary of Contents for BLAGDON HYDRATECH MULTI 800

Page 1: ... by Blagdon s award winning range of water gardening equipment As a result Blagdon s reputation for quality is unrivalled amongst experienced pond gardeners and retailers alike Blagdon The Pond Masters The name you can rely on Interpet Dorking Surrey RH4 3YX Leaflet Code POS 0008 IMPORTANT Please attach proof of purchase to this manual and file in a safe place THE POND MASTERS GUIDE TO HYDRATECH M...

Page 2: ...mp in pond 8 9 Maintenance and cleaning 9 Cleaning 9 Step by step guides 9 11 Routine maintenance 9 Monthly maintenance 10 Annual maintenance 11 Winter storage 11 Troubleshooting 12 Troubleshooting and maximising performance 12 Faults problem procedure 13 Consumer advice contact details 13 Returning faulty pumps 13 Guarantee 13 CONTENTS GETTING TO KNOW YOUR HYDRATECH MULTI PUMP OPENING AND CLOSING...

Page 3: ...6 Pump outlet hole N A 7 Pump support brackets N A 8 Filter cage hinges N A 1 2 4 5 6 7 8 3 GETTING TO KNOW YOUR HYDRATECH MULTI PUMP HYDRATECH MULTI 800 Hydratech Multi 800 No Part Description Spare Code 1 Pump motor unit N A 2 Impeller complete 1040815 3 Pump outlet N A 4 Impeller cover N A 5 Water bell 1040747 6 Double Daisy 1040747 7 23cm telescopic riser pipe 1040761 5 7 6 2 1 3 4 Parts 5 and...

Page 4: ...1040808 10 Water bell large 1014144 11 Daisy 3 stage 1040754 1 2 4 5A 5 5A 6 3 7 9 10 11 8 GETTING TO KNOW YOUR HYDRATECH MULTI PUMP HYDRATECH MULTI 6000 No Hydratech Multi 6000 Part Description Spare Code 1 Pump motor unit N A 2 Pump outlet N A 3 Impeller housing N A 4 Shaft locator 1017671 5 Ceramic shaft and locator 1017664 6 Impeller only 1017626 7 Impeller cover O ring 1017640 8 Impeller cove...

Page 5: ... a metal or plastic conduit to protect the cable Attention has been drawn to the fact that special rules may exist concerning the installation of your pond pump i e local building regulations These pumps must not be used in swimming pools or areas where people are in contact with the water Always disconnect the mains electricity supply whilst the equipment is being installed repaired maintained or...

Page 6: ... pre filter cleaning Fountain Make sure there is ample cable from mains supply Place pump in desired location Adjust telescopic riser pipe so fountain head is above surface of the pond Fountain height can now be adjusted see Adjusting dual control T piece diagram below not 800 model See Getting to know your Hydratech Multi for parts and descriptions Tip Ensure that any fountain waterfall filter or...

Page 7: ...used during the winter follow annual maintenance procedure and store frost free in the house or garage until spring MAINTENANCE CLEANING 10 11 MAINTENANCE CLEANING Remove impeller cover by pulling gently upwards from the base Remove impeller from pump motor Wash parts with fresh water carefully Monthly Maintenance Following as for Routine Maintenance steps 1 to 3 800 MODEL MONTHLY MAINTENANCE To c...

Page 8: ...mited to replacement of the faulty product only no other costs will be reimbursed This guarantee is not transferable and does not affect your statutory rights This guarantee does not confer any rights other than those expressly set out above Excludes impeller which may require replacing annually If any parts need replacing spares are available from your retailer GUARANTEE IMPORTANT Problem Low flo...

Reviews: