2
1. Install wall mount brackets above the opening, we recommend 1 bracket by each pulley and 1 bracket
every 24 in. When spliced, remove the belt fork from each track then slightly unscrew the 4 screws in
the connection plate. Now slide the connection plate into the tracks so that it is centred between the 2
spliced tracks. Tighten the 4 screws, starting with the outside first. One bracket should be placed on
each side of a splice.
Note: Double Wall Mount brackets also available for dual track
draperies or to extend a single track further from the wall.
Wall Mounting
2”
Ceiling Mounting
INSTALLATION
- BRACKETS (STRAIGHT TRACK)
When determining the correct mounting height,
note that the carrier attachment eye is centered
approximately 2” below the top of the track
Center opening
via Tandem motor
Brackets (Every 24”)
Finished Track Width
Splice (required for tracks over 16’)
Pulley
One Way
Brackets (Every 24 In.)
1.88 in. (47.8 mm)
3.75 in.
(95.3 mm)
Small
Pulley
Splice (required for tracks over 16’)
From the end
of the pulley
From the end
of the pulley
3.75”
3.75”