- 54 -
Typematic Rate (Chars/Sec)
This item sets how many times the keystroke will be repeated in a
second when you hold the key down.
Ø
The choice: 6, 8, 10, 12, 15, 20, 24, or 30.
Typematic Delay (Msec)
Sets the delay time after the key is held down before it begins to repeat
the keystroke.
Ø
The choice: 250, 500, 750, or 1000.
Security Option
If you have installed password protection, this item defines if the pass-
word is required at start up, or if it is only required when a user tries to
enter the setup utility.
Ø
The choice: System or Setup.
Note: To disabled security, select PASSWORD SETTING at Main
Menu, and then you will be asked to enter password. Do not
type anything and just press <Enter>; it will disable security.
Once the security is disabled, the system will boot, and you
can enter Setup freely.
OS Select For DRAM > 64MB
This item is required if you have installed more than 64MB of memory
and you running the OS/2 operation system. Otherwise, leave the item
at "Non-OS2" default.
Ø
The choice: Non-OS2 or OS2.
HDD S.M.A.R.T. Capability
The S.M.A.R.T. (Self-Monitoring, Analysis, and Reporting Technology)
system is a diagnostics technology that monitors and predicts device
performance. S.M.A.R.T. software resides on both the disk drive and the
host computer. The disk drive software monitors the internal perfor-
mance of the motors, media, heads, and electronics of the drive. The
host software monitors the overall reliability status of the drive. If a
device failure is predicted, the host software, through the Client
WORKS S.M.A.R.T applet, warns the user of the im-pending condition
and advises appropriate action to protect the data.
Ø
The choice: Enabled or Disabled.