background image

ENGLISH

2

OVERVIEW 
Front Panel

DFR22 FRONT PANEL

Figure 1

 1.

 

INPUT/OUTPUT Level Meters:

CLIP.

 Illuminates at 3 dB below clipping level.

0  VU

+4 dBu, –10 dBV; software selectable

. 0 dB is equal to

+4 dBu by default. If the input or output sensitivity is

changed to –10 dBV using the DFR22 software, 0 dB

equals –10 dBV.

–20 dB.

 Illuminates when the signal meets or exceeds the

indicated level.

MUTE.

 Illuminates when input or output is muted.

 2.

 

DFR Filter LEDs

. Illuminate when individual feedback filters

are active. When a filter changes or is added, an LED flashes,

then stays on.

 3.

 

AUTO CLEAR Buttons and LEDs. 

Press and release these

buttons to configure Auto Clear mode for each channel. Press

them again to activate Auto Clear. When an Auto Clear LED

illuminates, Auto Clear is active on its corresponding channel.

 4.

 

PRESS TO LOCK / HOLD TO CLEAR Button and LEDs.

Press this button to lock filters at their current values. Holding

this button down will reset all feedback filters, even if they are

locked. The LED lights to indicate that the lock is active.

 5.

 

BYPASS DFR FILTERS Button and LEDs.

 Press these but-

tons to suspend feedback reducer operation and remove feed-

back filters from the audio path. When a Bypass LED illumi-

nates, feedback reduction is bypassed on the corresponding

channel. Bypass does not affect other processors (such as

equalizers, delay, limiters, etc.).

 6.

 

LOAD Button.

 Press this button to activate a selected preset.

 7.

 

PRESET Indicator.

 Shows the number of the currently active

preset. Blinks to show the number of the other presets in the

DFR22 when pressing the SELECT buttons.

 8.

 

SELECT Buttons.

 Press to scroll through the presets stored

in the DFR22.

 9.

 

COMM LED.

 Flashes in unison with the feedback filter LEDs

when the detector is deploying a new filter or changing an ex-

isting one, and also blinks whenever the unit is communicating

with a connected computer.

 10.

 

RS232 Port.

 Connects the DFR22 to a computer.

 11.

 

POWER LED. 

Illuminates when 100–240 VAC power is is ap-

plied to the DFR22.

Back Panel

U.S. PATENT NO. 5,999,631

OTHER PATENT PROTECTION

APPLIED FOR

DFR22 REAR PANEL

Figure 2

 1.

 

Power Connector.

 Connects to 100–240 VAC power.

 2.

 

Shure Link Interface.

 Allows linking of up to 16 Shure Link de-

vices, which may be accessed by a computer.

 3.

 

3-Pin RS-232 Port.

 Connects the DFR22 to a computer. For

use with DFR22 software and control systems. Refer to the

Computer Connections section.

 4.

 

CONTROL IN Pins

. Use control input pins for remote control

of preset switching, muting, and gain. Refer to the Control Pin

Connections section.

 5.

 

DIP Switches.

 Use Switches 1–4 to select a Shure Link De-

vice ID. Use Switch 5 to lock or unlock front panel controls. Re-

fer to the Front Panel  Lockout  section for information on lock-

ing front panel controls.

 6.

 

Output Connectors (Phoenix).

 These active, cross–

coupled, balanced outputs can be used with balanced or un-

balanced inputs. They can be switched b4 dBu/–10

dBV line–level operation, using the DFR22 software. Refer to

the Audio Connections section.

 7.

 

Output Connectors ( XLR).

 These active, cross–coupled,

balanced outputs can be used with balanced or unbalanced in-

puts. They can be switched b4 dBu/–10 dBV line–lev-

el operation using the DFR22 software. Refer to the Audio

Connections section.

 8.

 

Input Connectors (Phoenix)

. These active balanced inputs

can be used with balanced or unbalanced outputs. They can-

not be used simultaneously with an XLR connector for the

same input. They can be switched b4 dBu/–10 dBV

line–level operation using the DFR22 software. Refer to the

Audio Connections section.

 9.

 

Input Connectors ( XLR). 

These active balanced inputs can

be used with balanced or unbalanced outputs. They cannot be

used simultaneously with a Phoenix connector for the same in-

put. They can be switched b4 dBu/–10 dBV line–level

operation using the DFR22 software. See Audio Connections

section for more information.

Summary of Contents for DFR22E

Page 1: ...DFR22 Audio Processor with Feedback Reduction 27B8813 Rev 200 Shure Incorporated Printed in U S A...

Page 2: ...NE PAS utiliser cet appareil proximit de l eau 6 NETTOYER UNIQUEMENT avec un chiffon sec 7 NE PAS obstruer les ouvertures de ventilation Installer en respectant les con signes du fabricant 8 Ne pas in...

Page 3: ...h input Each input is routed to each output S Preset selector and indicator for up to 16 presets S Control input pins for setting up remote preset volume and mute controls PACKING LIST S Power Cable S...

Page 4: ...ing with a connected computer 10 RS232 Port Connects the DFR22 to a computer 11 POWER LED Illuminates when 100 240 VAC power is is ap plied to the DFR22 Back Panel U S PATENT NO 5 999 631 OTHER PATENT...

Page 5: ...as fixed and will designate the remaining 11 filters as dynamic 3 The preset indicator will display a flashing h If you want Auto Clear to work automatically after a certain number of hours you must u...

Page 6: ...ck The DFR22 will automatically insert a notch filter to attenuate that frequency Once the system stops feeding back you can further raise the level and repeat the process for additional frequencies T...

Page 7: ...put LEDs will flash as shown in Figure 7 The DFR22 is ready to use once the LEDs stop flashing DFR22 INITIALIZATION Figure 7 AUDIO CONNECTIONS NOTE Audio will pass from the inputs to the outputs even...

Page 8: ...ntrol system to the 3 pin RS 232 Phoenix connector on the back panel of the DFR22 as shown in Figure 11 IMPORTANT You CANNOT connect two PCs to the DFR22 at the same time However you CAN connect an AM...

Page 9: ...used for preset control Any remaining pins can then be used to adjust gain or to mute channels The number of pins need ed for preset control depends on the type of control hardware used as well as the...

Page 10: ...ins When using a potentiometer the total resistance of the cable run should be less than 100 ohms When using momentary switches the total resistance of the cable run should be less than 100 ohms NOTE...

Page 11: ...are Kit 90AY8100 12 Block Connector Terminals 3 pin for audio inputs and outputs 2 Block Connector Terminals 10 pin for control inputs and outputs 4 Rackmount Screws and Washers Optional Accessories D...

Page 12: ...IMITED TWO YEAR WARRANTY Shure Incorporated Shure hereby warrants that this product will be free from defects in materials and workmanship for a period of two years from the date of purchase At its op...

Page 13: ......

Reviews: