background image

4. Use only submersible power supply wires supplied by pump

manufacturer. When lowering pump into well, secure supply
wires to discharge pipe at 10 ft. (3M) intervals with Scotch #33
electrical tape. DO NOT damage pump wires.

NOTICE: 

To avoid dropping pump down well or damaging wires

or splices, 

NEVER 

allow pump wires to support weight of pump.

PUMP INSTALLATION

1. If standard air over water pressure tank is used, install two

bleeder orifices about 2 ft. (.6M) apart as shown in Fig. 12.
Orifices will automatically charge the tank with air. See Fig. 12 to
determine orifice location.

NOTICE: 

If Pre-charged tank is used, DO NOT install bleeder

orifices. If pump and pre-charged tank are replacing a standard
tank system, remove bleeder orifices before installing pump in
well.

2. To prevent losing pump down the well, connect safety rope

strong enough to support pump and drop pipe (minimum 5/16"
(

8

mm) twisted polypropylene or pronila rope) to eyelet on pump

discharge. Tie off other end of safety rope securely to well seal,
well cap or pitless adapter.

3. Discharge outlet is 1-1/4" NPT threaded. 

Use 100 PSI (6

8

9.5kPa) rated polyethylene plastic pipe for

installations up to 100' (30.5M) depth.

Use 160 PSI (1103.2 kPa) rated polyethylene plastic for installa-
tions up to 220' (67.1M) depth.

For depths beyond 220' (67.1M) use galvanized steel pipe for
the entire drop pipe.

INITIAL START-UP/NEW WELLS

NOTICE: NEVER

operate pump with discharge valve completely

closed. Pump can destroy itself if run with discharge shut off (“dead-
headed”) and warranty will be void.

NOTICE: 

To avoid sand-locking pump, follow procedure below

when starting pump for the first time. 

NEVER 

start a pump with dis-

charge completely open unless you have done this procedure first.

1. Connect a pipe elbow, a short length of pipe and a gate valve to

pump discharge at well head (see Fig. 10).

2. Mount motor control box (3-wire pump) or fused disconnect

switch (2-wire pump) in a permanently weatherproof place. Make
sure that controls will not be subjected to extreme heat or excess
moisture.

3. Make sure controls are in OFF position.
4. Connect motor leads and power supply to motor control box or

magnetic starter (see Installation Wiring Diagrams). 

DO NOT

START PUMP YET.

5. Set gate valve on discharge 1/3 open; start pump (see Fig. 10).
6. Keep gate valve at this setting while water pumps out on ground.

Let run until water is clear of sand or silt. (To check solids in
water, fill a glass from pump and let solids settle out).

7. When water is completely clear at 1/3 setting, open gate valve to

approximately two-thirds open and repeat process.

8

. When water is completely clear at 2/3 setting, open gate valve

completely and run pump until water is completely clear.

9. Remove gate valve for permanent installation near tank (see

Figs. 11 and 12).

10. Install sanitary well seal or pitless adapter unit, well unit, electri-

cal conduit and surface piping. Installation must meet all code
requirements that apply.

CONNECTING TO TANK/
WATER SYSTEM

Hazardous pressure. Submersible pumps can

develop very high pressure in some situations. To prevent tank
blowup, install a pressure relief valve able to pass full pump
flow at 75 PSI (517.1kPa) when using an air over water pressure
tank. Install a pressure relief valve capable of passing entire
pump flow at 100 PSI (690 kPa) when using a pre-charged pres-
sure tank. Install this relief valve between pump and tank.

Pipe joint compound can cause cracking in plastics.

Use only teflon tape on joints in plastic pipe.

NOTICE: 

Allowing pump or piping system to freeze may severely dam-

age pump and will void warranty. Protect pump and entire piping system
(including pressure tank) from freezing.

PRE-CHARGED PRESSURE TANK HOOKUP

See Fig. 11 for piping connections to pre-charged pressure tank.

NOTICE: 

Check air pre-charge in tank before starting pump. Adjust

pre-charge to 2 PSI (13.

8

 kPa) below pump cut-in setting, (ie, a pre-

charge tank used with a 30-50 switch should be pre-charged with air
to 2

8

 PSI (193.1 kPa). Adjust pre-charge by adding or bleeding air

through tire valve located on top of tank. Check pre-charge annually
and adjust as needed.

STANDARD TANK HOOKUP

See Fig. 12 for piping connections to standard pressure tank and for
correct distance of bleeder orifices from pressure tank.

5

Control

center

or

electrical

disconnect

box

Temporary wiring

to control center or

electrical disconnect box

Temporary piping

Gate valve

Pump in well

Pump installation

for developing a well

6

8

9 0993

Figure 10 – Temporary Connections while cleaning well
for start-up.

Important Electrical Grounding Information

Hazardous voltage. Can shock, burn,
or kill. To reduce the risk of electrical

shock during pump operation, ground and bond the pump and
motor as follows:

A. To reduce risk of electrical shock from metal parts of the assembly

other than the pump, bond together all metal parts accessible at
the well head (including metal discharge pipe, metal well casing,
and the like). Use a metal bonding conductor at least as large as
the power cable conductors running down the well to the pump's
motor. 

B. Clamp or weld (or both if necessary) this bonding conductor to the

grounding means provided with the pump, which will be the equip-
ment-grounding terminal, the grounding conductor on the pump
housing, or an equipment-grounding lead. The equipment-ground-
ing lead, when provided, will be the conductor having green insula-
tion; it may also have one or more yellow stripes.

C. Ground the pump, motor, and any metallic conduit that carries

power cable conductors. Ground these back to the service by con-
necting a copper conductor from the pump, motor, and conduit to
the grounding screw provided within the supply-connection box
wiring compartment. This conductor must be at least as large as
the circuit conductors supplying the pump

Save these instructions.

Summary of Contents for SD-A200

Page 1: ...SATION Pompe submersible de 4 po à deux et trois fils de 1 2 à 1 1 2 CV 60 Hz MANUAL DEL USUARIO Bombas Sumergibles de 4 de dos y tres alambres de 1 2 a 1 1 2 hp 60 Hz CONSUMER HOT LINE 1 800 535 4950 Monday Friday 7 AM to 5 PM EST SD A300 SD A301 SD A302 SD A314 SD A3183 SD A3184 SD A3065 SD A3067 SD A3207 SD A31015 SD A30610 SD A200 SD A201 SD A202 SD A203 SD A214 ...

Page 2: ...ivery damage Report any damage immediately to shipping carrier or to your dealer Well driller should thoroughly develop well pump out all fine sand and foreign matter before pump is installed See Initial Startup Pump performance is based on pumping clear cold water with no entrained air Warranty is void in the following conditions Pump has pumped excessive sand which can cause premature wear to pu...

Page 3: ...re Green Control box is not required See Figure 1B for correct hook up information for 230 Volt 2 Wire motors only Fig 1B Single phase 2 Wire Connections Follow color coding when connecting control box Yellow to Y Red to R Black to B 3 NOTE 1 Maximum wire lengths shown maintain motor voltage at 95 of service entrance voltage running at maximum nameplate amperes If service entrance voltage will be ...

Page 4: ...er will not supply enough heat NOTICE Keep torch moving Too much concentrated heat may damage tubing see Fig 6 3 Mechanical Splice Kit with plastic insulators for 14 12 and 10 Gauge AWG Wire 2 3 and 5mm2 A Cut off motor leads Stagger lead and wire length so that 2nd lead is 4 101 6mm longer than 1st lead and 3rd lead is 4 101 6mm longer than second B Cut off wire ends Match colors and lengths of w...

Page 5: ...eal or pitless adapter unit well unit electri cal conduit and surface piping Installation must meet all code requirements that apply CONNECTING TO TANK WATER SYSTEM Hazardous pressure Submersible pumps can develop very high pressure in some situations To prevent tank blowup install a pressure relief valve able to pass full pump flow at 75 PSI 517 1kPa when using an air over water pressure tank Ins...

Page 6: ...le Union Submersible motor control 3 wire models Electrical disconnect Pressure gauge Air volume control Pressure switch To house service Gate valve Relief valve 2 ft 6m See table Figure 11 Typical Pre Charge Tank Installation Figure 12 Typical Standard Tank Installation CUT IN CUT OFF Pre charge Tank PSI kPa PSI kPa PSI kPa 20 137 9 40 275 8 18 124 2 30 206 8 50 344 7 28 193 1 40 275 8 60 413 7 3...

Page 7: ... nameplate or on circuit Use only control box designed for use with pump rating diagram inside control box cover Wire size too small Check wire size against chart Page 3 Install correct wire size Pump starts too frequently Leaks in system Check all tank connections with soapsuds for air leaks System must be air and water tight Check plumbing for leaks Pressure switch Check for defective switch or ...

Page 8: ...misapplication tampering alteration nor due to improper installation operation maintenance or storage nor to other than normal application use or service including but not limited to operational fail ures caused by corrosion rust or other foreign materi als in the system or operation at pressures in excess of recommended maximums Requests for service under this warranty shall be made by returning ...

Page 9: ...rteur ou au dis tributeur L aménagement du puits doit être entièrement terminé avant de procéder à l installation de la pompe extraire par pompage toutes les particules de sable fin et les impuretés Voir Démarrage initial Le rendement de la pompe est évalué en fonction d un pompage d eau claire et froide sans entraînement d air La garantie est annulée dans les circonstances suivantes La pompe a ex...

Page 10: ...s d alimentation en courant rouge noir et un conducteur de terre vert Une boîte de commande n est pas requise Voir la Figure 1B concernant les informations du bon branchement des moteurs de 230 volts à 2 conducteurs seulement 10 REMARQUE 1 Les longueurs maximum de câblage assurent une tension moteur représentant 95 de la tension de service admise en fonctionnement maximum selon le nombre d ampères...

Page 11: ...our nissent pas assez de chaleur REMARQUE Déplacer constamment la flamme du chalumeau Une concentration excessive de la flamme risque d endommager le gainage voir Fig 6 3 Kit de raccordement mécanique avec isolants en plastique pour types de fils AWG de calibre 14 12 et 10 2 3 et 5 mm2 A Sectionner les fils conducteurs du moteur Échelonner la longueur des conducteurs et des fils électriques de la ...

Page 12: ... le robinet vanne en vue de son installation définitive près du réservoir voir Fig 11 et 12 10 Monter le plombage sanitaire du puits ou l ensemble adaptateur sans cavité le puits la canalisation électrique et la tuyauterie en surface L installation doit satisfaire à tous les codes et réglementations qui s appliquent CONNEXION AU RÉSERVOIR CIRCUIT D EAU Pression dangereuse Les pompes submersibles p...

Page 13: ... 124 2 18 206 8 30 344 7 50 193 1 28 275 8 40 413 7 60 262 38 DISTANCE SÉPARANT LE CLAPET DE LA PRISE DE PURGE SUPÉRIEURE VOLUME DU RÉSERVOIR LITRES DISTANCE EN m pi gallons U S 159 42 0 6 2 310 4 82 0 9 3 454 2 120 1 5 5 832 7 220 1 5 5 1192 3 315 3 10 1987 1 525 4 6 15 Couvercle de puits ventilé Boîte de com mande 3 types de câblage Sectionneur de courant Réservoir à pression préchargée Manocont...

Page 14: ...e schéma du circuit couvercle de la boîte commande conçue spécialement pour cette pompe de commande Calibre de fil trop mince Comparer le calibre du fil avec le tableau de la page 10 Installer le fil du type qui convient La pompe démarre trop fréquemment Présence de fuites dans le circuit Contrôler les connexions des tuyaux du réservoir en utilisant de Le circuit doit être étanche à l air et à l e...

Page 15: ...s ou entretenus correctement ni à ceux qui n ont pas été utilisés ou entretenus normalement y compris mais sans s y limiter aux produits ayant des pannes de fonctionnement causées par la corrosion la rouille ou autre corps étranger dans le système ou à des produits ayant fonctionné à des pressions dépassant la limite maximale recommandée Les demandes de service en vertu de la présente garantie ser...

Page 16: ...fectamente el pozo bombearlo hasta extraer toda la arena fina y materiales extraños antes de que se instale la bomba Véase Puesta en Marcha Inicial Los valores de rendimiento de la bomba se basan en el bombeo de agua limpia y fría sin arrastre de aire La garantía es nula en las siguientes condiciones La bomba ha bombeado un exceso de arena que puede causar el des gaste prematuro de la bomba Véase ...

Page 17: ...nductores tienen dos conductores de alimentación Rojo Negro y un conductor de tierra Verde No se requiere una caja de control Ver Figura 1B para la información de conexión correcta de los motores de dos conductores de 230 Voltios solamente Figura 1B Conexiones de los motores de dos conductores monofásicos Cuando conecte la caja de control siga las siñas de color Amarillo para Y Rojo para R Negro p...

Page 18: ...que calor en forma pareja con un soplete un fósforo o un encendedor no dan suficiente calor AVISO Mantenga el soplete en movimiento Un exceso de calor concen trado puede dañar el tubo de plástico véase fig 6 3 Empalme mecánico con aisladores plásticos para alambre calibre 14 12 y 10 AWG 2 3 y 5 mm2 A Corte los conductores del motor Escalone las longitudes de estos conductores y el alambre de maner...

Page 19: ...tire la válvula de cortina para su instalación permanente cerca del tanque véanse las figs 11 y 12 10 Instale un sello sanitario para pozo o una unidad adaptadora la unidad del pozo los conductos para cables eléctricos y las tuberías de superficie La instalación debe respetar todas las exigencias de los códigos que sean procedentes CONEXIÓN AL TANQUE SISTEMA DE AGUA Presión peligrosa En determinad...

Page 20: ...4 2 30 206 8 50 344 7 28 193 1 40 275 8 60 413 7 38 262 DISTANCIA DE LA VÁLVULA DE RETENCIÓN AL ORIFICIO DE PURGA SUPERIOR CAPACIDAD DEL DISTANCIA en PIES m TANQUE en GALONES l 42 159 2 0 6 82 310 4 3 0 9 120 454 2 5 1 5 220 832 7 5 1 5 315 1192 3 10 3 525 1987 1 15 4 6 Tapa ventilada de pozo Caja de control modelos de 3 alambres Desconector eléctrico Tanque de presión precargado Interruptor de pr...

Page 21: ...n la bomba en el interior sobre la tapa de la caja de control El diámetro de los conductores es Verifique el diámetro de los conductores en el cuadro de la página 17 Instale alambrado de diámetro correcto demasiado pequeño La bomba arranca con demasiada frecuencia Hay pérdidas en el sistema Verifique todas las conexiones del tanque con solución jabonosa para El sistema debe estar herméticamente se...

Page 22: ...traindicadas manejo indebido alteraciones ni debido a instalación funcionamiento mantenimien to o almacenaje incorrectos ni a ninguna otra cosa que no sea su aplicación uso o servicio normales in cluyendo pero no limitado a fallas operacionales cau sadas por corrosión oxidación u otros elementos extra ños en el sistema o funcionamiento a presión por enci ma del máximo recomendado Los pedidos de se...

Page 23: ...23 ...

Reviews: