background image

Warranty

6

For parts or assistance, call Shur-Dri Customer Service at 

1-800-535-4950

RETAIN ORIGINAL RECEIPT FOR YOUR RECORDS.

LIMITED WARRANTY

SHUR-DRI 

w

arrants to the original consumer purchaser (“Purchaser” or “You”) of its products that they are free from

defects in material and 

w

orkmanship for a period of t

w

elve (12) months from the date of the original consumer purchase.

If, 

w

ithin t

w

elve (12) months from the original consumer purchase, any such product shall prove to be defective, it shall be

repaired or replaced at SHUR-DRI’s option, subject to the terms and conditions set forth belo

w

. The original purchase

receipt and product 

w

arranty information label are required to determine 

w

arranty eligibility. Eligibility is based on purchase

date of original product – not the date of replacement under 

w

arranty. The 

w

arranty is limited to repair or replacement of

product only – Purchaser pays all removal, installation, labor, shipping, and incidental charges.

For parts or troubleshooting assistance, DO NOT return product to your retail store. Contact SHUR-DRI Customer Service
at 

1-800-535-4950

.

Claims made under this 

w

arranty shall be made by returning the product (except se

w

age pumps, see belo

w

) to the retail

outlet 

w

here it 

w

as purchased immediately after the discovery of any alleged defect. SHUR-DRI 

w

ill subsequently take 

corrective action as promptly as reasonably possible. No requests for service 

w

ill be accepted if received more than 

30 days after the 

w

arranty expires.

Warranty does not apply to products used in commercial/rental applications.

SEWAGE PUMPS

DO NOT return a se

w

age pump (that has been installed) to your retail store. Contact SHUR-DRI Customer Service.

Se

w

age pumps that have seen service and been removed carry a contamination hazard 

w

ith them.

If your se

w

age pump has failed:

Wear rubber gloves 

w

hen handling the pump;

For 

w

arranty purposes, return the pump’s cord tag and original receipt of purchase to the retail store;

Dispose of the pump according to local disposal ordinances.

Exceptions to the Twelve (12) Month Limited Warranty

Product

Warranty Period

Models SD106, SD107, SD-108

90 Days

Models SDAS3, SDVS3, SDSU25, SD-CUST

2 Years

Model SDAS5

3 Years

Pre-Charge Water System Tank

5 Years

Se

w

age Pump (Model SDLTW50), 

Submersible Sump Pump (Models SDLT50 and SDLT75)

Lifetime

General Terms and Conditions

You must pay all labor and shipping charges necessary to replace product covered by this 

w

arranty. This 

w

arranty does 

not apply to the follo

w

ing: (1) acts of God; (2) products 

w

hich, in SHUR-DRI’s sole judgement, have been subject to 

negligence, abuse, accident, misapplication, tampering, or alteration; (3) failures due to improper installation, operation,
maintenance or storage; (4) atypical or unapproved application, use or service; (5) failures caused by corrosion, rust or
other foreign materials in the system, or operation at pressures in excess of recommended maximums.

This 

w

arranty sets forth SHUR-DRI’s sole obligation and purchaser’s exclusive remedy for defective products.

SHUR-DRI SHALL NOT BE LIABLE FOR ANY CONSEQUENTIAL, INCIDENTAL, OR CONTINGENT DAMAGES 
WHATSOEVER.

THE FOREGOING WARRANTIES ARE EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS AND IMPLIED 
WARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND 
FITNESS FOR A PARTICULAR PURPOSE. THE FOREGOING WARRANTIES SHALL NOT EXTEND BEYOND THE
DURATION PROVIDED HEREIN.

Some states do not allo

w

 the exclusion or limitation of incidental or consequential damages or limitations on ho

w

 long an

implied 

w

arranty lasts, so the above limitations or exclusions may not apply to You. This 

w

arranty gives You specific legal

rights and You may also have other rights 

w

hich vary from state to state.

SHUR-DRI PUMP COMPANY • 293 Wright St. • Delavan, WI U.S.A. 53115

Phone: 1-800-535-4950

Web Site: http://www.shur-dri.com

Summary of Contents for SD-108

Page 1: ...N WI 53115 SD891 Rev 5 26 10 INSTALLATION MANUAL 12V DC FLEXVANE PUMP Pages 2 6 MANUEL D INSTALLATION POMPE FLEXVANE FONCTIONNANT SUR LE COURANT CONTINU DE 12 VOLTS Pages 7 11 MANUAL DE INSTALACIÓN BOMBA FLEXVANE DE 12V CC Pages 12 16 CONSUMER HOT LINE 1 800 535 4950 Monday Friday 7 30 AM to 5 PM CST ...

Page 2: ...hock disconnect the wiring before servicing Hazardous electrical current Battery current can cause severe burns and start a fire if the battery is short circuited 2 Know the pump application limitations and poten tial hazards 3 Pump water only with this pump NOTICE This unit is not designed as a waterfall or fountain pump or for applications involving salt water or brine Use with waterfalls founta...

Page 3: ... lead wires as indicated in Table I and as shown in Figure 1 NOTICE In order for the pump to run in the proper direction the wires must be connected correctly 8 Power Supply Pump is designed for use with a 12 Volt DC battery Operation requires a minimum 12 Volt power supply OPERATION Risk of electric shock Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface or...

Page 4: ...earplate 9 Install the new impeller Be sure to align the flat on the impeller with the flat on the motor shaft See Figure 3 10 While installing the impeller twist it in a clockwise direction See Figure 4 11 Reinstall the outer wearplate and O Ring 12 Reinstall the cover plate 13 Reinstall the screws Tighten the screws moderately first and then snug them down TO REPLACE THE FUSE Refer to Figure 5 1...

Page 5: ... 12 Motor 1 13 Cord Set 1 992 695 14A Fuse Holder 1 U17 1148 14B Fuse 1 344 001 15 Pud L Scoop 1 992 653 REPAIR PARTS LIST Not illustrated If the motor fails replace the pump TROUBLESHOOTING SYMPTOM PROBABLE CAUSE S CORRECTIVE ACTION Pump will not prime There are leaks in the Be certain all connections are air tight Test the connections suction line by putting soap suds on them If there is a leak ...

Page 6: ...r rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period Models SD106 SD107 SD 108 90 Days Models SDAS3 SDVS3 SDSU25 SD CUST 2 Years Model SDAS5 3 Years Pre Charge Water System Tank ...

Page 7: ...rancher le câblage avant d intervenir sur cet équipement Courant électrique dangereux Le courant de la batterie risque de causer de graves brûlures et un incendie peut être provoqué si la batterie est mise en court circuit 2 Il faut connaître les méthodes d utilisation de cette pompe les limitations de son utilisation et les risques potentiels de danger que cela présente 3 Ne pomper que de l eau a...

Page 8: ...ur que la pompe puisse fonctionner dans le bon sens les fils doivent être correctement branchés 8 Courant d alimentation La pompe est conçue pour fonc tionner sur une batterie de 12 volts en courant continu Les conditions de fonctionnement de cette pompe exigent une alimentation électrique d au moins 12 volts FONCTIONNEMENT Risque de secousses électriques Ne pas manipuler la pompe ni le moteur de ...

Page 9: ...arbre du moteur Se reporter à la Figure 3 10 Pendant la pose de l impulseur le tourner à droite Se reporter à la Figure 4 11 Reposer la plaque d usure extérieure et le joint torique 12 Reposer la plaque couvercle 13 Reposer les vis et les serrer tout d abord modérément puis fermement POUR REMPLACER LE FUSIBLE se reporter à la Figure 5 1 Prudemment séparer le porte fusible puis déposer le fusible s...

Page 10: ...te pas La pompe n est pas Se reporter aux opérations d amorçage de la pompe que adéquatement amorcée l on trouvera dans la section Installation à la page 3 Réf Désignation Qté SD 108 1 Vis du couvercle 4 670 656 2 Plaque couvercle 1 230 298 3 Joint torique 1 546 023 4A Plaque d usure extérieure 1 721 122 4B Plaque d usure intérieure 1 721 122 5 Impulseur 1 416 011 6 Anneau elliptique 1 134 007 7 J...

Page 11: ...outchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie Modèles SD106 SD107 SD 108 90 jours Modèles SDAS3 SDVS3 SDSU25 SD CUST 2 ans Modèles SDAS5 3 ans Réservoir p...

Page 12: ...cables antes de realizar trabajos de reparación o mantenimiento Corriente eléctrica peligrosa La corriente de la batería puede causar quemaduras graves y comenzar un incendio si hay un corto circuito en la batería 2 Es importante conocer los usos de la bomba sus limita ciones y posibles peligros 3 Bombee solamente agua con esta bomba AVISO Este aparato no está diseñado como bomba de cascada o fuen...

Page 13: ...se ilustra en la Figura 1 AVISO Para que la bomba marche en la dirección correcta se deben conectar los cables en forma correcta 8 Suministro de corriente La bomba ha sido diseñada para usarse con una batería de CC de 12 voltios La operación requiere un mínimo de alimentación de 12 voltios OPERACIÓN Riesgo de choque eléctrico No se debe manipular una bomba o un motor de bomba con las manos mojadas...

Page 14: ... placa de desgaste exterior y el aro tórico 12 Vuelva a instalar la placa de cubierta 13 Vuelva a instalar los tornillos Apriete los tornillos primero moderadamente y después ajústelos bien CAMBIO DEL FUSIBLE Consulte la Figura 5 1 Separe el portafusible delicadamente y saque el fusible usado consulte el paso 1 2 Empuje el nuevo fusible con firmeza hacia arriba y hacia adentro del portafusible con...

Page 15: ...que se esté está a más de 10 pies por bombeando debajo de la bomba La bomba no bombea La bomba no se cebó Consulte los pasos para cebar la bomba que vienen debidamente incluidos en la sección de Instalación en la página 3 Clave Descripción de No la pieza Cant SD 108 1 Tornillo cubierta 4 670 656 2 Placa de cubierta 1 230 298 3 Aro tórico 1 546 023 4A Placa de desgaste exterior 1 721 122 4B Placa d...

Page 16: ...oacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bomba y el recibo de compra original a la tienda minorista Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminación Excepciones para la Garantía Limitada de Doce 12 Meses Producto Período de garantía Modelos SD106 SD107 SD 108 90 ...

Reviews: