background image

Safety

2

For parts or assistance, call Shur-Dri Customer Service at 

1-800-535-4950

READ AND FOLLOW 

SAFETY INSTRUCTIONS!

This is the safety alert symbol.

When you see this

symbol on your pump or in this manual, look for

one of the following signal words and be alert to the
potential for personal injury.

warns about hazards that 

will 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

can 

cause serious

personal injury, death or major property damage if
ignored.

warns about hazards that 

will 

or 

can 

cause

minor personal injury or property damage if ignored.

The label 

NOTICE 

indicates special instructions which

are important but not related to hazards.

Carefully read and follow all safety instructions in this
manual and on pump.

Keep safety labels in good condition. 
Replace missing or damaged safety labels.

DESCRIPTION

This non-corrosive pump, with reversible flow direction,
is designed to pump water only.  

Risk of fire or explosion. Can cause severe
injury, property damage or death. 

Do not

use in explosive atmospheres. Pump water only with this
pump.

SPECIFICATIONS

Liquid Temp. Range ........... 35° to 120° F (1.7° to 50° C)

NOTICE: Never

operate the pump for more than two

hours at a time.  

Never 

run the pump dry! 

PERFORMANCE

DC MOTORS

1. DC motors must be connected to a fully charged

automotive, tractor or marine type battery of the
proper voltage.

2. Life expectancy of the motor is 500 to 1000 hours. 
3. Keep the motor dry at all times. 

For more information, see your retailer, or call Shur-Dri 
customer service at 1-800-535-4950.

GENERAL SAFETY INFORMATION

1. This equipment is only for use with an automotive,

tractor or marine type battery fully charged to 12
Volts DC.

Electrocution Hazard. Hazardous volt-

age can shock, burn, or kill.

To reduce the risk of elec-

tric shock, disconnect the wiring before servicing.

Hazardous electrical current. Battery

current can cause severe burns and start a fire if the
battery is short circuited.

2. Know the pump application, limitations, and poten-

tial hazards.

3. Pump water only with this pump.

NOTICE:

This unit is not designed as a waterfall or

fountain pump, or for applications involving salt
water or brine! Use with waterfalls, fountains, salt
water or brine will void warranty.
Do not use where water recirculates.
Not designed for use as a swimming pool drainer.

4. Release all pressure within the system before servic-

ing any component.

5. Drain all water from the system before servicing.
6. Secure the discharge line before starting the pump.

An unsecured discharge line can whip, possibly caus-
ing personal injury and/or property damage.

7. Check hoses for weak or worn condition before each

use, making certain all connections are secure.

8. Periodically inspect the pump and system compo-

nents. Keep free of debris and foreign objects.
Perform routine maintenance as required. See the
Maintenance Section.

9. Provide a means of pressure relief for pumps whose

discharge line can be shut-off or obstructed.

10. Personal Safety:

a. Wear safety glasses at all times when working

with the pumps.

b. Keep work area clean, uncluttered and properly

lighted.

c. Keep visitors at a safe distance from the work

area.

d. Make the workshop child-proof – with padlocks,

master switches, and by removing starter keys.

11. When wiring a DC pump, follow all of the electrical

and safety codes that apply.

12. All wiring is to be 12 gauge stranded copper wire that

is:
A. Water resistant
B. Oil resistant
C. Flame resistant

NOTICE:

This pump is equipped with a Permanent

Magnet Type 12 Volt Reversible DC motor. Be sure it
is connected properly as illustrated for the direction
of flow indicated by the arrows on the pump case
(see Figure 1, Page 3).

GPH (LPH) AT TOTAL FEET (M) OF LIFT

Model

0’ 10’

20’

40’

45’

No.

(0)

(3m)

(6.1m) (12.2m) (13.7m)

450

390

300

130

0

SD-108

(1703)

(1476)

(1135)

(492)

(0)

Summary of Contents for SD-108

Page 1: ...N WI 53115 SD891 Rev 5 26 10 INSTALLATION MANUAL 12V DC FLEXVANE PUMP Pages 2 6 MANUEL D INSTALLATION POMPE FLEXVANE FONCTIONNANT SUR LE COURANT CONTINU DE 12 VOLTS Pages 7 11 MANUAL DE INSTALACIÓN BOMBA FLEXVANE DE 12V CC Pages 12 16 CONSUMER HOT LINE 1 800 535 4950 Monday Friday 7 30 AM to 5 PM CST ...

Page 2: ...hock disconnect the wiring before servicing Hazardous electrical current Battery current can cause severe burns and start a fire if the battery is short circuited 2 Know the pump application limitations and poten tial hazards 3 Pump water only with this pump NOTICE This unit is not designed as a waterfall or fountain pump or for applications involving salt water or brine Use with waterfalls founta...

Page 3: ... lead wires as indicated in Table I and as shown in Figure 1 NOTICE In order for the pump to run in the proper direction the wires must be connected correctly 8 Power Supply Pump is designed for use with a 12 Volt DC battery Operation requires a minimum 12 Volt power supply OPERATION Risk of electric shock Do not handle a pump or pump motor with wet hands or when standing on wet or damp surface or...

Page 4: ...earplate 9 Install the new impeller Be sure to align the flat on the impeller with the flat on the motor shaft See Figure 3 10 While installing the impeller twist it in a clockwise direction See Figure 4 11 Reinstall the outer wearplate and O Ring 12 Reinstall the cover plate 13 Reinstall the screws Tighten the screws moderately first and then snug them down TO REPLACE THE FUSE Refer to Figure 5 1...

Page 5: ... 12 Motor 1 13 Cord Set 1 992 695 14A Fuse Holder 1 U17 1148 14B Fuse 1 344 001 15 Pud L Scoop 1 992 653 REPAIR PARTS LIST Not illustrated If the motor fails replace the pump TROUBLESHOOTING SYMPTOM PROBABLE CAUSE S CORRECTIVE ACTION Pump will not prime There are leaks in the Be certain all connections are air tight Test the connections suction line by putting soap suds on them If there is a leak ...

Page 6: ...r rubber gloves when handling the pump For warranty purposes return the pump s cord tag and original receipt of purchase to the retail store Dispose of the pump according to local disposal ordinances Exceptions to the Twelve 12 Month Limited Warranty Product Warranty Period Models SD106 SD107 SD 108 90 Days Models SDAS3 SDVS3 SDSU25 SD CUST 2 Years Model SDAS5 3 Years Pre Charge Water System Tank ...

Page 7: ...rancher le câblage avant d intervenir sur cet équipement Courant électrique dangereux Le courant de la batterie risque de causer de graves brûlures et un incendie peut être provoqué si la batterie est mise en court circuit 2 Il faut connaître les méthodes d utilisation de cette pompe les limitations de son utilisation et les risques potentiels de danger que cela présente 3 Ne pomper que de l eau a...

Page 8: ...ur que la pompe puisse fonctionner dans le bon sens les fils doivent être correctement branchés 8 Courant d alimentation La pompe est conçue pour fonc tionner sur une batterie de 12 volts en courant continu Les conditions de fonctionnement de cette pompe exigent une alimentation électrique d au moins 12 volts FONCTIONNEMENT Risque de secousses électriques Ne pas manipuler la pompe ni le moteur de ...

Page 9: ...arbre du moteur Se reporter à la Figure 3 10 Pendant la pose de l impulseur le tourner à droite Se reporter à la Figure 4 11 Reposer la plaque d usure extérieure et le joint torique 12 Reposer la plaque couvercle 13 Reposer les vis et les serrer tout d abord modérément puis fermement POUR REMPLACER LE FUSIBLE se reporter à la Figure 5 1 Prudemment séparer le porte fusible puis déposer le fusible s...

Page 10: ...te pas La pompe n est pas Se reporter aux opérations d amorçage de la pompe que adéquatement amorcée l on trouvera dans la section Installation à la page 3 Réf Désignation Qté SD 108 1 Vis du couvercle 4 670 656 2 Plaque couvercle 1 230 298 3 Joint torique 1 546 023 4A Plaque d usure extérieure 1 721 122 4B Plaque d usure intérieure 1 721 122 5 Impulseur 1 416 011 6 Anneau elliptique 1 134 007 7 J...

Page 11: ...outchouc pour manipuler la pompe À des fins de garantie retourner l étiquette figurant sur le cordon de la pompe et l original du reçu au détaillant Mettre la pompe au rebut conformément à la réglementation locale Exceptions à la garantie limitée de douze 12 mois Produit Période de garantie Modèles SD106 SD107 SD 108 90 jours Modèles SDAS3 SDVS3 SDSU25 SD CUST 2 ans Modèles SDAS5 3 ans Réservoir p...

Page 12: ...cables antes de realizar trabajos de reparación o mantenimiento Corriente eléctrica peligrosa La corriente de la batería puede causar quemaduras graves y comenzar un incendio si hay un corto circuito en la batería 2 Es importante conocer los usos de la bomba sus limita ciones y posibles peligros 3 Bombee solamente agua con esta bomba AVISO Este aparato no está diseñado como bomba de cascada o fuen...

Page 13: ...se ilustra en la Figura 1 AVISO Para que la bomba marche en la dirección correcta se deben conectar los cables en forma correcta 8 Suministro de corriente La bomba ha sido diseñada para usarse con una batería de CC de 12 voltios La operación requiere un mínimo de alimentación de 12 voltios OPERACIÓN Riesgo de choque eléctrico No se debe manipular una bomba o un motor de bomba con las manos mojadas...

Page 14: ... placa de desgaste exterior y el aro tórico 12 Vuelva a instalar la placa de cubierta 13 Vuelva a instalar los tornillos Apriete los tornillos primero moderadamente y después ajústelos bien CAMBIO DEL FUSIBLE Consulte la Figura 5 1 Separe el portafusible delicadamente y saque el fusible usado consulte el paso 1 2 Empuje el nuevo fusible con firmeza hacia arriba y hacia adentro del portafusible con...

Page 15: ...que se esté está a más de 10 pies por bombeando debajo de la bomba La bomba no bombea La bomba no se cebó Consulte los pasos para cebar la bomba que vienen debidamente incluidos en la sección de Instalación en la página 3 Clave Descripción de No la pieza Cant SD 108 1 Tornillo cubierta 4 670 656 2 Placa de cubierta 1 230 298 3 Aro tórico 1 546 023 4A Placa de desgaste exterior 1 721 122 4B Placa d...

Page 16: ...oacal ha fallado Use guantes de caucho cuando manipule la bomba Para los fines de la garantía devuelva la etiqueta del cordón de la bomba y el recibo de compra original a la tienda minorista Descarte la bomba cumpliendo con todas las normas locales que correspondan para su eliminación Excepciones para la Garantía Limitada de Doce 12 Meses Producto Período de garantía Modelos SD106 SD107 SD 108 90 ...

Reviews: