P/N 1808554 Rev. D
8
Hydraulic Pump Installation
- continued
NOTE:
To thread fitting body onto end of hose, turn body
counterclockwise until body engages hose about 1". Thread
fitting insert onto body, turning clockwise until insert is snug
against body. Fitting must be threaded completely onto
hoses to prevent leaking.
hose
reusable
fitting
body
reusable
fitting
insert
STEP 5:
Connect negative wire from battery to stud on hydrau
-
lic pump.
STEP 6:
Connect positive wire from battery to circuit breaker
and from circuit breaker to solenoid on pump.
STEP 7:
Place solenoid cover over solenoid. Secure cover to
pump with 8" cable tie.
CAUTION
Replace shipping plug with breather cap on hydrau-
lic pump or pump will be damaged.
!
STEP 3:
Connect hoses from hydraulic pump to hydraulic
cylinder, making sure hose clamps are tight around
reservoir.
battery
hydraulic
pump
solenoid
reservoir
hydraulic
cylinder
hydraulic
hoses
hose
clamp
breather
cap
fill
port
+
_
solenoid
solenoid
cover
cable
tie
STEP 4:
Remove shipping plug from fill port and fill pump with
approximately 4 quarts Dexron automatic transmis
-
sion fluid. Install breather cap onto fill port. Do not
reinstall shipping plug.
150a
circuit
breaker
p
/
n
1800458