Manual of SR258 intelligent controller
40
Manually.
Note:
When manual mode is activated, sign blinks on the screen, controller runs
for 15 minutes and then switch-off all output, control exits manual mode automatically.
Menu structure
Main Menu
Submenu Factory set Adjustable range
Description
MAN
Manual mode
R1
OFF
ON/OFF
R1 on and off
R2
OFF
ON/OFF
R2 on and off
R3
OFF
ON/OFF
R3 on and off
HR
OFF
ON/OFF
HR on and off
Function setup
►Press “▲”, “R1” displays on the screen
►Press “SET”, “R1 OFF” displays
►Press “SET”, “OFF” blinks
►Press “▲/▼”, to activate this function, “R1 ON” displays
►Press “SET” or “ESC” to save the setting
►Press “▲”, “R2” displays, repeat above steps to set the manual output of R2, R2, HR.
7.8 BLPR Blocking protection
Function description:
In order to protect the pumps against blocking after standstill, the controller is equipped with
a blocking protection function. This function switches on the relays one after another every
day at 12:00 a.m and pump runs for 10s at 100 % speed.
Menu structure