Manual of SR258 intelligent controller
23
Setup the functions
► Select “LOAD” main menu
► Press “SET”, “DTO 6K” displays on the screen
► Press “SET”, “6K” blinks
► Press”▲/▼”, to adjust the switch-on temperature of the
solar circuit pump.
► Press “SET” or “ESC” to save the setting
► Press “▲”, “DTF 4K” displays on the screen
► Press “SET”, “4K” blinks
► Press “▲/▼”, to adjust the switch-off temperature of solar circuit pump
► Press “SET” or “ESC” to save the setting
► Press “▲”, “DTS 10K” displays on the screen
► Press “SET”, “10K” blinks
► Press “▲/▼”, to adjust the standard temperature difference of solar circuit pump
► Press “SET” or “ESC” to save the setting
► Press “▲”, “RIS 2K” displays on the screen
► Press “SET”, “2K” blinks
► Press “▲/▼”, to adjust the rise range of pump speed control
► Press “SET” or “ESC” to save the setting
► Press “▲”, “SMX 70
o
C” displays on the screen
► Press “SET”, “70
o
C” blinks
► Press “▲/▼”, to adjust the maximum temperature of tank
► Press “SET” or “ESC” to save the setting
► Press “▲”, “SMAX S3” displays on the screen
► Press “SET”, “S3” blinks
► Press “▲/▼”, select the sensor for maximum temperature of tank (S3 for T3, S2 for T2)
► Press “SET” or “ESC” to save the setting
► Press “▲”, “HYST 2K” displays on the screen
► Press “SET”, “2K” blinks
► Press “▲/▼”, to adjust the hysteresis of tank maximum temperature
► Press “SET” or “ESC” to save the setting
7.3 COL Collector function
Function description
OCEM Collector emergency shutdown