![Shuangri Electron SR258 Operation Manual Download Page 40](http://html.mh-extra.com/html/shuangri-electron/sr258/sr258_operation-manual_1260877040.webp)
Manual of SR258 intelligent controller
39
►Press “▲”, “AHO 40
o
C”displays on the screen
►Press “SET”, “40
o
C” blinks
►Press “▲/▼”, to adjust the switch-on temperature
►Press “SET” or “ESC” to save the setting
►Press “▲”, “AHF 45
o
C”displays on the screen
►Press “SET”, “45
o
C”” blinks
►Press “▲/▼”, to adjust the switch-off temperature
►Press “SET” or “ESC” to save the setting
►Press “▲”,
“tA1O 00:00”
displays on the screen
►Press “SET”, hour “00” blinks
►Press “▲/▼”, to adjust the hour of start time of the first time section
►Press “SET”, minute “00” blinks
►Press “▲/▼”, to adjust the minute of start time of the first time section
►Press “SET” or “ESC” to save the setting
►Press “▲”,
“tA1F 23:59”
displays on the screen
►Press “SET”, hour “23” blinks
►Press “▲/▼”, to adjust the hour of close time of the first time section
►Press “SET”, minute “59” blinks
►Press “▲/▼”, to adjust the minute of close time of the first time section
►Press “SET” or “ESC” to save the setting
►Press “▲”, to access the second time section setting, same like above steps to set the
second, the third time section.
If you want cease the thermostat function within a time section, then just set its start time and
close time with a same value. (Example: 10:00 start, 10:00 close also)
BEEP
(
Beeper warning function
)
setting
►Press “▲”, select BEEP submenu, “BEEP” displays on the screen
►Press “SET”, “BEEP OFF” displays on the screen
►Press “SET”, “OFF” blinks
►Press “▲/▼”, to activate this function, “BEEP ON” displays on the screen
►Press “SET” or “ESC” to save the setting
7.7 MAN Manual operation
For control and service work, the operating mode of the relays can be manually adjusted. For
this purpose, select the adjustment menu MAN (for R1, R2, R3, HR) to set output “On/OFF”