Manual of SR288 intelligent controller
48
►Press “SET” or “ESC” to save the setting
7.12 FS Flow meter selection and flow rate monitoring
Under this menu, it is possible to set the flow meter (VFS, FRT) on or off and set its
measuring range.
FLOW (flow monitoring)
Function description
Flow monitoring function is designed to detect whether flow exists in the solar system and
therefore to switch-off the corresponding pump in case of no flow, it can avoid damaging of
the solar system, for example, avoiding pump dry running
If relay R1 is powered, flow rate of flow sensor will be monitored. After a delay detection time
(DELA), if no flow rate is detected, error message will appear, and sign will blinks
on the screen.
If “OFF” option of the flow monitoring function is activated, and then the loaded tank is
stopped to be heated until error message is removed, then monitoring function is activated
again.
Note
: if the selected flow meter is not connected to the controller, sign will blinks
on the screen.
Menu structure
Main
men
u
Submen
u
1
Submen
u 2
Submen
u 3
Factor
y set
Adjusta
ble
range
Step
per
adjust
Descriptio
n
FS
Register
flow meter
sensor
GFDS
VFS
OFF
OFF
OFF
/
ON
Groudfos
flow meter
sensor