Manual of SR288 intelligent controller
38
3. Temperature of object tank is lower than its preset maximum temperature.
When the preset temperature difference is exceeded, pump speed control starts. For every
increase or decrease by the rise value, the pump speed will be adjusted by 10 %.
BEEP Beeper fault warning
When system has fault (temperature sensor fault, no flow), beeper sends out warning.
Menu structure
Main
menu
Submenu
1
Submenu 2
Factory
set
Adjustable
range
Step per
adjust
Description
AUX
Auxiliary functions
SFB
OFF
ON/OFF
Solid fuel boiler function
DTSO
6K
1-50K
0.5K
Switch-on temperature
difference of SFB
DTSF
4K
0.5-49.5K
0.5K
Switch-off temperature
difference of SFB
DTSS
10K
1.5-50K
0.5K
Pump speed control-
temperature difference
RISF
2K
1-20K
1K
Pump speed control- rise
range
MXSS
60
℃
0.5-95
℃
0.5
℃
Maximum switch-off
temperature of tank
heating
MNSO
60
℃
0.5-89.5
℃
0.5
℃
Minimum switch-on
temperature of solid fuel
boiler
HEAT
0FF
ON/OFF
Heat transferring between
tanks