Manual of SR288 intelligent controller
31
• PHEA: PWM profile heating pump
• 0-10: Speed control via 0 - 10 V signal
Note:
1. More information about connection of high efficiency pump see the paragraph (3.5
Connection with high efficiency pump)
2. Minimum pump speed: Under the adjustment menu MIN1 (2), a relative minimum speed
for connected pumps can be allocated to the outputs R1, R2.
3. Maximum pump speed: Under the adjustment menu MAX1 (2), a relative maximum
speed for connected pumps can be allocated to the outputs R1, R2.
4. When the devices which are not speed-controlled are used (e. g. motored valves), the
pump speed value of the corresponding relay must be set to 100 % or the control Mode
must be set to ONOF in order to deactivate pump speed control.
Note:
PWM Relay allocation: PWM1 for R1, PWM2 for R2
Menu structure