5
3. Welcome Interface :
First Line: Product model and software version
Second Line: Equipment series number
4. Main Interface:
FIRE 1 M:2CH-P
P:75
V:13.6
First Line: Fire address and Safe address on the DMX ChannelMode(2CH-P ); DMX address on
the DMX ChannelMode( 6CH / 2CH-N );
Second Line: Pressure75 (e.g. 100=10bar); V: 13.6 means internal voltage is 13.6V.
5. Alert Message:
Alert Message
Explanation
E0
Test Mode
Safety lock located at TEST MODE
Factory Mode
DMX signal blocked in factory mode
E1 Pressure Err
Pressuriser for about 10s, pressure value failed to reach 100%, system
will report E1. Possible fault: No fuel, pump failure, pipeline problem
etc.
E2 P Relief Err
Pipeline can't release pressure leads to pressure relief error.
Possible fault: pressure release valve failure, pipeline problem or
control system problem etc.
E5 Voltage Err
Battery voltage>18V or <9V for continuous 5s, machine stops running.
Possible fault: the battery is low
E6 Tip Err
if the machine slant over 45° , it stops running, system will report E6
6. Interface setup:
Press “MENU” to switch through setup menu:
DMX Channel Mode
Menu
Range
Explanation
6CH / 2CH-N
Set DMX Address
1~512
DMX address setup
2CH-P
Fire Address
1~512
Fire address setup
Safety Address
1~512
Safety address setup
7. Advanced Interface:
Press “MENU” 3s enter advanced interface, press “MENU” to switch interface, press “MENU” 3s
can back to main interface.
Items
Contents
Description
Drive Test
OFF / Pump / Igniter /
Relief Valve / Jet Valve
1.
Pump
Pump running 1s, if pressure reached the
target value, the pump will not running.
2.
Igniter
Ignite 1s
3.
Relief Valve
Release valve will be on and off for 3 times