4. DMX CONTROL (2CH-P, 2CH Professional Mode)
Channel
Function
CH-F
Ignition ON/OFF: (0~110) Ignition OFF, (111~255) Ignition ON. The default value
F=1
CH-S
Mode setup: (0~49) Pressure Relief Mode (Emergency Stop), (50~200)
Compression Mode, (201~255) Pressure Relief Mode (Emergency Stop). The
default value S=2
Note: F = Fire Address ; S = Safety Address.
5. DMX CONTROL (6CH, 6CH Mode )
Channel
Function
CH-1
--none--
CH-2
--none--
CH-3
Ignition ON/OFF: (0~253) Ignition OFF, (254~255) Ignition ON
CH-4
Firing Duration setup: 0 and 255 is permanent fire (8s is limit duration time);
1~254 is 10~2540ms duration time
(Manual firing duration = DMX Value * 10ms)
CH-5
--none--
CH-6
Mode setup: (0~49) Pressure Relief Mode (Emergency Stop), (50~200)
Compression Mode, (201~255) Pressure Relief Mode (Emergency Stop)
6. DMX CONTROL (2CH-N
,
2CH Normal Mode)
Channel
Function
CH-1
Ignition ON/OFF: (0~110) Ignition OFF, (111~255) Ignition ON
CH-2
Mode setup: (0~49) Pressure Relief Mode (Emergency Stop), (240~255) Compression
Mode
▲
SHOWVEN host controller ZK6200/ZK6300
1. Hardware description:
\ MODEL: X-F1800
\ DIMENSION: 590×360×370mm
\ WEIGHT: 30kg
\ VOLTAGE: 100-240V, 50/60Hz
\ POWER: 380W
\ CONTROL: DMX
\ INTERFACE: Neutrik
®
powerCON TRUE1 IN/OUT
Neutrik
®
3-pin& 5-pin XLR IN/OUT
9V-60V Fireworks igniter signal port
\ FLAME HEIGHT: up to 8-10m (no wind)
\ ROTATE ANGLES: 210°(±105°)
\ FUEL: ISOPAR-G, H, L, M; ISOPROPANEL, BIOETHANOL
\ FUEL TANK CAPACITY: 10L
\ FUEL CONSUMPTION RATE: 60ml/s
\ EXT. BATTERY POWERED: YES