1

 

USER MANUAL

  

uFlamer

 

 Please read this manual carefully before operating this product. 

 Warranty card attached in the manual, please keep it well. 

Warning 

Unauthorized repair are prohibited, it may cause serious incident 

Make sure power supply in consistent with the rated voltage of the equipment, and the socket 

must well grounded. Unplug and turn off the machine when not use 

Before connect the power cable, communication DMX cable should well connected and ensure 

the command keep at firing OFF status. And safety lock stay at test mode 

The device can only be placed horizontally. Safety distances are marked on the device (at least 

15m in projection direction, at least 5m around the device) 

After turning on the device, no person allows to stay in the danger area. Ensure all persons that 

are part of the show be informed about the safety distance, risks and functions of the device 

Always have a CO2 fire extinguisher and an extinguishing blanket in case of needed 

If there be any doubt as to the safety operation of the device in any circumstances, the device 

should  be  taken  out  of  service  immediately.  Be  sure  the  device  is  in  good  operating  condition 
before use. If fail to fire correctly, immediately shut down and check it accordingly 

Be  sure  to  use  high  quality  flame  fluid,  otherwise,  it  is  easily  lead  to  failure  or  danger.  Be 

careful when refill the flame fluid tank. Please keep flame fluid away from heat source, sparks, 
fire or other possibility of ignition. Do not smoke! 

The operator responsible for the control of uFlamer must always have a clear view of the device, 

so that he/she can stop the show immediately when there is danger. The main AC power switch 
should near operator. So that operator can turn off the power of all devices in case of abnormal 

The device shall not be altered and applied to other use purpose 

 

Disclaimers: 

SHOWVEN  technologies Co., Ltd excludes liability  for unsafe  situations, accidents  and damages 
resulting from: 
1. Ignoring warnings or regulations as shown on flamer or this manual. 
2. Use for other applications or circumstances other than those indicated herein. 
3. Changes to the flamer, including use of non-original spare parts. 
4. Removed safety cover without authorization from SHOWVEN.  
5. Use this machine by unqualified or untrained personnel. 
6. Improper use of machine. 

Foreword 

Thanks  for  choosing  uFlamer.  Please  read  following  manual  carefully  and  completely  before 
operating  this  product.  Operate  according  to  instructions  is  very  important  for  safety,  and  can 
elongate the service life of the machine 
Strictly  follow  the  instruction  in  the  manual  when  operate  uFlamer.  If  you  have  any  doubts, 
please contact SHOWVEN technologies Co., Ltd by [email protected] 
We  assume  the  person  who  use  or  come  in  contact  with  the  device  are  familiar  with  how  the 
device should be handled. This includes proper use, maintenance and repair of the machine  as 
defined in this user manual. 

Summary of Contents for uFlamer

Page 1: ...1 USER MANUAL uFlamer V1 0 2021 03 23 Showven Technologies Co Ltd ...

Page 2: ... the flame fluid tank Please keep flame fluid away from heat source sparks fire or other possibility of ignition Do not smoke The operator responsible for the control of uFlamer must always have a clear view of the device so that he she can stop the show immediately when there is danger The main AC power switch should near operator So that operator can turn off the power of all devices in case of ...

Page 3: ...ent control system safer for use Standard DMX control compatible with all DMX console Neutrik powerCON TRUE1 connectors Built in battery support 10min continuous firing or 3 days standby Fitted with fireworks igniter signal port can be triggered by fireworks igniter Built in wireless control with radio range up to 1km Technical Specifications Model uFlamerTM DIMENSION 330 260 320mm WEIGHT 14kg VOL...

Page 4: ...3 Structure of uFlamer 1 Firing Box 2 Top Panel 3 Fuel Bottle Area 4 Control Panel 5 Safety Loop Overview of Bottom Panel ...

Page 5: ...herwise no DMX signal ERR Light on when there is an error PUMP Light on when pump is running 2 Button Funtions MENU Switch interface to setup parameter Parameter Up Parameter Down ENTER Confirm and save parameters screen will flash when parameters saved Note screen display will switch to main interface if don t press button for a long time ...

Page 6: ...f error Possible fault pressure release valve failure pipeline problem or control system problem etc E5 Voltage Err Battery voltage 18V or 9V for continuous 5s machine stops running Possible fault the battery is low E6 Tip Err if the machine slant over 45 it stops running system will report E6 6 Interface setup Press MENU to switch through setup menu DMX Channel Mode Menu Range Explanation 6CH 2CH...

Page 7: ...ces for uFlamer is at least 15m in projection directions and 5m around AC 100V 240V 50 60Hz MADE IN CHINA Showven Technologies Co Ltd www showven cn info showven cn 86 731 83833068 Building B1 Changsha E Center Liuyang Economic Development Zone Hunan China WARNING Hazardous voltage inside please do not remove the cover unless by trained personnel People and flammable materials should keep a minimu...

Page 8: ... LED is off Before operate machine please locate safety lock at TEST MODE TEST MODE operator can test the ignition of the flamer but the fuel ejection function disabled so there is no fuel eject USER MODE the device can generate flames normally Please strictly follow the safety distance requirement remove all human animal or flammable objects in the danger area Fueling Please fueling with high qua...

Page 9: ... distance requirement remove all human animal or flammable objects in the danger area Compression Host controller Press pre heat button both of the lights on Firing Host controller Press FIRING key Pressure Relief Relief pressure when shows finished or uFlamer not use for a long period Host controller Press pre heat key both of the lights off Switch safety lock to TEST MODE Press the button off Th...

Page 10: ...n DMX Value 10ms CH 5 none CH 6 Mode setup 0 49 Pressure Relief Mode Emergency Stop 50 200 Compression Mode 201 255 Pressure Relief Mode Emergency Stop 6 DMX CONTROL 2CH N 2CH Normal Mode Channel Function CH 1 Ignition ON OFF 0 110 Ignition OFF 111 255 Ignition ON CH 2 Mode setup 0 49 Pressure Relief Mode Emergency Stop 240 255 Compression Mode SHOWVEN host controller ZK6200 ZK6300 1 Hardware desc...

Page 11: ...i input 5 RDMX monitoring function system can send back circle flamer working status info such as pressure warming etc and display on the screen 6 Emergency stop function 3 Operational Panel 1 Cable Connection Area AC Input AC Power Input CAN CAN communication input output MIDI In Midi time synchronous signal input DMX 512 DMX signal input output LAN network interface USB program download interfac...

Page 12: ...ain menu F2 File selection F3 Configuration F4 About host controller 5 Edit Control Area Set circle flamer DMX address as below FLAMER No DMX address 1 1 2 7 3 13 4 19 5 25 6 31 7 37 8 43 9 49 10 55 11 61 12 67 13 73 14 79 15 85 ...

Page 13: ...zarion CIRCLE FLAMER No 1 10 From 1 15 Steppsequence short 2 4s F I L E NO Terminal Monitor FIRING HEIGHT 31 0 5s DURTN F I R I N G TRIG DELAY 0 0s 10 0s 1 REPEAT COUNTS REPEAT DELAY 1 1 7 13 2 8 14 3 9 15 4 10 16 5 11 17 6 12 18 MAIN FILE SELECT CONFIG ABOUT 1 Set the FIRING DURTN REPEAT PERIOD and REPEAT COUNTS values ignore SEQUENCE setting on uFlamer 2 Press Pre heat to activate the compressio...

Page 14: ...hape is seriously deformed or the fuel injection line is significantly deformed or coarsened the nozzle should be removed immediately for cleaning 4 Maintenance of the O ring If it is found that the O ring of the nozzle is damaged or ageing when cleaning the nozzle the O ring should be replaced in time material and size of O ring fluororubber O ring the outermost diameter is 14 mm and the line dia...

Page 15: ...ithout factory permission Below situations NOT included in warranty service 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without Showven s permission 3 Damage caused by external reasons lightning strike power supply etc 4 Damage caused by improper installation or use For product damage not incl...

Page 16: ...Tel 86 731 83833068 Web www showven cn E mail info showven cn Add Liuyang Economic Development Zone Changsha 410300 Hunan Province P R China ...

Reviews: