Note: wrong DMX address setup may leads to flamer out of control.
Host controller ZK6200 setup as below:
1. Press “F3” enter host controller configuration menu, DEVICE choose “CIRCLE FLAMER” as
below.
2. Set Start No. and End No. of device.
F3 CONFIG
End No.
: 10
Device
: CIRCLE FLAMER
Mode Selection
: User Mode
DMX IN
: ON
Repeat Time Mode
: Repeat Period Mode
DMX Address
: 1
CAN
: OFF
Trigger Source
: HAND
Audio Level
: 2
Audio Filter Delay
: 100ms
Start No.
:
1
Press “F1” back to main interface.
F1 MAIN
Synchronizarion CIRCLE FLAMER No. 1-10
From 1-15 Steppsequence short 2.4s
F I L E
NO.
Terminal
Monitor
FI RI NG
HEIGHT
31
0.5s
DURTN
F I R I N G
TRIG
DELAY
0.0s
10.0s
1
REPEAT
COUNTS
REPEAT
DELAY
1
1
7
13
2
8
14
3
9
15
4
10
16
5
11
17
6
12
18
MAIN
FILE SELECT
CONFIG
ABOUT
1. Set the FIRING DURTN, REPEAT PERIOD and REPEAT COUNTS values. (ignore SEQUENCE setting
on uFlamer)
2. Press “Pre-heat” to activate the compression of device.
3. Press the “Firing” to make a show.
Note: Put safety lock at “TEST MODE” to check the signal connection and nozzle status before
use the device for firing. For Emergency stop, press “PRE-HEAT”, device will enter pressure relief
mode, and stop emergently.
Battery and Maintenance
1. Battery Recommendation