background image

22

Summary of Contents for Circle Flamer X-F1800

Page 1: ...USER MANUAL CIRCLE FLAMER X F1800 V1 2 Showven Technologies Co Ltd ...

Page 2: ...ease keep flame fluid away from heat source sparks fire or other possibility of ignition Do not smoke The operator responsible for the control of Circle Flamer must always have a clear view of the device so that he she can stop the show immediately when there is danger The main AC power switch should near operator So that operator can turn off the power of all devices in case of abnormal The devic...

Page 3: ...m no wind with 210 105 swiveling angles As much as 70 preset flame sequences are available It is easier and stable to running the CIRCLE FLAMER when controlled by SHOWVEN original host controller ZK6200 6300 MODEL Circle Flamer X F1800 Dimension 590 x 360 x 370mm Input AC100 240V 50 60Hz Work power 380W Interface Double DMX Interface 9V 60V Fireworks igniter signal port Control Standard DMX Effect...

Page 4: ...5 pin DMX socket 7 110V 220V Power socket 8 Fuse 9 ON OFF switch 10 12V Battery socket 11 DC 9V 60V fireworks igniter signal port 1 Handle 2 Firing Nozzle 3 Top Panel 4 Fuel Bottle Area 5 Control Panel 6 Safety Loop Connection dimension diagram of bottom bracket of the flamer 203 5 352 540 M10 φ 3 4 f i x i n g h o l e 241 M10 1 8 9 10 11 2 3 4 5 6 7 ...

Page 5: ...Light on when pump is running 2 Button Funtions MENU Switch interface to setup parameter Parameter Up Parameter Down ENTER Confirm and save parameters screen will flash when parameters saved Note screen display will switch to main interface if don t press button for a long time First Line Product model and software version number Second Line Equipment factory number First Line DMX address Second L...

Page 6: ...ow if the machine slant over 45 it stops running system will report E6 Alert Message E0 System Lock E1 Pressure Err E2 P Relief Err E3 Motor Err When Ext Ignite is ON device will pressuriser automatically when switch safety lock to USER MODE decompression when switch to TEST MODE 9V 60V fireworks ignitor signal will trigger related firing sequences E4 Ext Ignition E5 Voltage Err E6 Tip Err DMX sig...

Page 7: ...ry Mode Normal Mode ON OFF YES NO Trigger through 5 60V fireworks ignitor signal Preset sequence triggered by fireworks ignitor Language switch Factory mode is for test in factory only Turn ON OFF tip over function Reset default parameter settings Swiveling and stop at target angle Pump running 1s if pressure reached the target value the pump will not running Ignite 1s Release pressure 1s Safety l...

Page 8: ...ocate safety lock at TEST MODE TEST MODE operator can test the rotate of nozzle but the fuel ejection function disabled so there is no fuel eject and flames USER MODE the device can generate flames normally Please strictly follow the safety distance requirement remove all human animal or flammable objects in the danger area The device can only be placed horizontally if placed on truss please locke...

Page 9: ...DMX console switch DMX value of channel 6 to 0 49 201 255 8 Check device status in TEST MODE 9 Pressure Relief Host controller Press pre heat button light on DMX console switch DMX value of channel 6 to 50 200 11 Pressuriser Set firing sequence Host controller Press FIRING key DMX console switch DMX value of channel 3 to 254 255 12 Firing Relief pressure when show finished or CIRCLE FLAMER not use...

Page 10: ...uarantee safety use for next time 14 Switch safety lock to TEST MODE Power off CIRCLE FLAMER tear down power cable and DMX cable pack up the device when it is cooled down 15 Power off NO 8 0 N O 1 1 0 5 NO 2 90 N O 3 7 5 N O 4 6 0 N O 5 4 5 NO 6 30 NO 7 15 NO 9 15 NO 10 30 N O 1 1 4 5 N O 1 2 6 0 N O 1 3 7 5 NO 14 90 N O 1 5 1 0 5 L M R ...

Page 11: ...it need 90ms when operator design a show to synchronize to music this drive time must be calculated Angle 90 75 60 45 30 105 15 15 30 45 60 75 0 90 105 Drive time needed 150ms 130ms 110ms 90ms 70ms 170ms 50ms 50ms 70ms 90ms 110ms 130ms 0ms 150ms 170ms No NO 2 NO 3 NO 4 NO 5 NO 6 NO 1 NO 7 NO 9 NO 10 NO 11 NO 12 NO 13 NO 8 NO 14 NO 15 ...

Page 12: ... Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition SHORT flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition LONG flame Single Ignition ...

Page 13: ...lame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence LONG flame Step sequence 1 35s 3 01s 3 01s 2 67s 2 67s 1 35s 80 81 82 84 85 86 87 89 90 91 92 94 97 99 100 101 102 104 105 107 108 109 95 96 110 112 113 114 115 117 120 122 123 124 125 127 128 130 118 119 L R R L L R R L L R R L R L M L R L R M R L R L L R R L L R L R R L L R L R R L M L R L R M R L R L R...

Page 14: ...6 DMX CONTROL Channel CH1 CH2 CH3 CH4 CH5 CH6 Additional Sequences List No 63 64 65 66 67 68 70 69 Firing Duration For reference 0 60s 0 60s 1 38s 1 38s 1 85s 1 85s 4 18s 4 18s CH5 DMX Reference Value 161 163 164 165 166 168 169 170 171 173 174 175 179 181 176 178 Ignition angle NO Description Nozzle Movement Step 2 14 SHORT flame Step sequence Step 14 2 Step 2 14 Step 14 2 Step 8 14 Step 8 2 Step...

Page 15: ...annel activates the actual ignition If the DMX value of this channel higher than 253 the CIRCLE FLAMER will ignite The fourth channel is the firing duration setup Below formula can be used to calculate the firing duration ms DMX Value t 10 Channel Explanation DMX value 127 5 1 2145 1 The first channel controls the firing angle It defines to which angle the nozzle of CIRCLE FLAMER move to The angle...

Page 16: ...1 Set nozzle straight up CH1 Angle 128 CH2 Speed 0 CH3 Ignition 0 CH4 Firing duration 0 CH5 Program sequence 0 CH6 Compres sion mode 50 200 2 Set preset Sequence No 31 CH1 Angle 128 CH2 Speed 0 CH3 Ignition 0 CH4 Firing duration 0 CH5 Program sequence DMX value 80 CH6 Compression mode 50 200 3 Ignition CH1 Angle 128 CH2 Speed 0 CH3 Ignition 255 CH4 Firing duration 0 CH5 Program sequence DMX value ...

Page 17: ... controller introduction 3 Operational Panel a Standard DMX512 signal output b Support 18units CIRCLE FLAMER ZK6200 or 54units CIRCLE FLAMER ZK6300 at the same time c 5 standard dynamic modes Synchronization Center to Ends Ends to Center Left to Right Right to Left And an user defin able Special Effect mode support 8 files each file support 36000 lines maximum effects lasts for 30min d Multi trigg...

Page 18: ...tput MIDI In Midi time synchronous signal input DMX 512 DMX signal input output LAN network interface USB program download interface SparkularEdit200 software port F1 Main menu F2 File selection F3 Configuration F4 About host controller There are 5 standard dynamic mode and 1 special effects mode Each mode support 8 files it can be switched easily on the mode selection area ...

Page 19: ... 16 91 17 97 18 103 Set circle flamer DMX address as below Note wrong DMX address setup may leads to circle flamer out of control 1 Press F3 enter host controller configuration menu DEVICE choose CIRCLE FLAMER as below 2 Set Start No and End No of device Setup of Host controller Press F1 back to main interface ...

Page 20: ...nance of the nozzle Nozzle need to be cleaned up and it is recommended that once every six months depending on the environ ment and frequency of use In the process of using the equipment if the flame shape is seriously deformed or the fuel injection line is signifi cantly deformed or coarsened the nozzle should be removed immedi ately for cleaning 3 Maintenance of the O ring If it is found that th...

Page 21: ...rvice for machines which with hardware malfunction except for the instrument damage caused by human factors in warranty period Please don t repair machine without factory permission 1 Damage caused by improper transportation usage management and maintenance or damage caused by human factors 2 Disassemble modify or repair products without Showven s permission 3 Damage caused by external reasons lig...

Page 22: ...21 ...

Page 23: ...22 ...

Page 24: ...hnologies Co Ltd Add Building B1 Changsha E Center No 18 Xiangtai Road Liuyang Economic Development Zone Changsha City 410300 Hunan Province P R China Tel 86 731 83833068 Web www showven cn E mail info showven cn ...