14
DMX Value = 2 + Sequence No.*2.55
CH2: Speed Setup
DMX value
Speed
0
Max Speed
1-254
Incremental of Speed
255
Max Speed
> Channel 2 (CH2): Speed Setup
> Channel 5 (CH5): Program Sequence setup
CH3: Ignition
0-253
254-255
CIRCLE FLAMER ignites
Manual Firing Duration setup
DMX value
1
10ms
0
Permanent
2
20ms
3
30ms
4
40ms
254
............
2540ms
255
Permanent
Firing Duration
> Channel 4 (CH4): Firing Duration setup
Firing sequence mode/related firing channel
DMX value
0~2
N/A
3~5
1
6~7
2
8~10
3
............
179~181
70
Sequence No.
11~12
4
The second channel defines the rotate speed. It work together with Channel 1 for manual firing.
DMX value
Ignition
CIRCLE FLAMER won’t ignite
> Channel 3 (CH3): Ignition ON/OFF
The third channel activates the actual ignition. If the DMX value of this channel higher than 253, the CIRCLE FLAMER will
ignite.
The fourth channel is the firing duration setup.
Below formula can be used to calculate the firing duration (ms):
DMX Value = t/10
• Channel Explanation
DMX value=127.5+
(∠
*1.2145
)
1. The first channel controls the firing angle. It defines to which angle the nozzle of CIRCLE FLAMER move to. The angle can
be chosen anywhere between -105° to +105° (DMX value 0 to 255).
2. The DMX value for angle of 0° is 127.5 (round up 128). Use this value, following formula can be used to calculate all other
angles
∠
in degree. Please always note the prefix of the angle.
The fifth Channel allows to firing a preset sequence. Three DMX values can be used for one of the programmed firing
sequence from above sequence list (refer to above sequence list table).
Below formula can be used to calculate firing sequence:
Summary of Contents for Circle Flamer X-F1800
Page 1: ...USER MANUAL CIRCLE FLAMER X F1800 V1 2 Showven Technologies Co Ltd ...
Page 22: ...21 ...
Page 23: ...22 ...