13
Function
Manual Angle setup:
(0~255) angle change from -105° to 105°, (128) is straight upward (0°).
Manual Speed setup:
(0) Max Speed, (1~254) Speed increase, (255) Max Speed.
Firing Ignition ON/OFF:
(0~253) Ignition OFF, (254~255) Ignition ON..
Firing Duration setup:
0 and 255 is permanent fire (10s is limit duration time);
1~254 is 10~2540ms duration time (Manual firing duration = DMX Value * 10ms).
Program sequence setup:
(0-2) no preset sequence; (3-255) preset sequence.
DMX value = 2 + Sequence No.*2.55 (ROUND OFF).
Firing Pressure setup:
(0~49) Pressure Relief Mode (Emergency Stop), (50~200) Pressure Armed
Mode, (201~255) Pressure Relief Mode (Emergency Stop)
6. DMX CONTROL
Channel
CH1
CH2
CH3
CH4
CH5
CH6
Additional Sequences List
No.
63
64
65
66
67
68
70
69
Firing Duration
(For reference)
0.60s
0.60s
1.38s
1.38s
1.85s
1.85s
4.18s
4.18s
CH5 DMX
Reference Value
161-163
164-165
166-168
169-170
171-173
174-175
179-181
176-178
Ignition
angle NO.
Description
Nozzle
Movement
Step 2>14
SHORT flame Step sequence
Step 14>2
Step 2>14
Step 14>2
Step 8>14
Step 8>2
Step 8>2
Step 8>14
SHORT flame Step sequence
LONG flame Step sequence
LONG flame Step sequence
SHORT flame Step sequence
SHORT flame Step sequence
LONG flame Step sequence
LONG flame Step sequence
L->R
R->L
L->R
R->L
M->L
M->R
M->R
M->L
-90°
-75°
-60°
-45°
-30°
-105°
-15°
15°
30°
45°
60°
75°
0°
90°
105°
> Channel 1 (CH1): Angle Setup
Angle No.
2
1
3
4
5
6
7
10
8
0
18
36
54
73
91
109
165
128
9
146
12
11
13
14
183
201
219
237
15
255
Angle
DMX value
Summary of Contents for Circle Flamer X-F1800
Page 1: ...USER MANUAL CIRCLE FLAMER X F1800 V1 2 Showven Technologies Co Ltd ...
Page 22: ...21 ...
Page 23: ...22 ...