background image

 

  

  

 

 

 

Ordercode: 43157 

X-Terminator 

 

 

The X-Terminator can be placed on a flat stage floor or mounted to any kind of truss with a clamp. 

 

Improper installation can cause serious damage to people and property! 

 

 

Connection with the mains 

Connect the device to the mains with the power-plug. 

Always pay attention, that the right color cable is connected to the right place. 

 

International 

EU Cable 

UK Cable 

US Cable 

Pin 

BROWN

 

RED

 

YELLOW/COPPER

 

PHASE

 

BLUE BLACK SILVER NEUTRAL 

 

YELLOW/GREEN GREEN 

GREEN PROTECTIVE 

GROUND 

 

Make sure that the device is always connected 

properly 

to the earth! 

 

 

 

 

 

 

Summary of Contents for X-Terminator

Page 1: ...X Terminator V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43157 MANUAL ENGLISH ...

Page 2: ...ntrol Modes 13 One X Terminator Stand alone 13 One X Terminator Sound controlled 13 Multiple X Terminators Master Slave Mode 13 Multiple X Terminators DMX Control 14 Fixture Linking 15 Data Cabling 15 Control Panel 16 Control Mode 16 DMX Addressing 16 Menu Overview 17 Main Menu Options 18 1 Built in Shows 18 2 Sound controlled Effect 18 3 Master Slave Mode 18 4 DMX Mode 18 5 System Settings 19 DMX...

Page 3: ...g material for inspection if any parts appear damaged from shipping or the carton itself shows signs of mishandling Save the carton and all packing materials In the event that a fixture must be returned to the factory it is important that the fixture be returned in the original factory box and packing Your shipment includes Showtec X Terminator IEC power cable 1 75 m 2 keys for the Interlock Mount...

Page 4: ...nto the sky Never open the laser housing The high laser power levels inside of the protective housing can start fires burn skin and will cause instant eye injury Do not insert objects into air vents Do not connect this device to a dimmerpack Do not open the device and do not modify the device Do not point lasers at highly reflective surfaces such as windows mirrors and shiny metal Even laser refle...

Page 5: ...alled out of the reach of children Never leave the unit running unattended Never attempt to bypass the thermostatic switch or fuses For replacement use fuses of same type and rating only The operation of a class 3B laser show laser is only allowed if the show is controlled by a skilled and well trained operator familiar with the data included in this manual The user is responsible for correct posi...

Page 6: ...or authorized training organization are allowed to use class 3B lasers in public The Laser Safety Officer is responsible for all aspects when using this laser including following all locally applicable safety laws and regulations The manufacturer will not accept liability for damages caused by the misuse or incorrect installation of this laser CAUTION AVOID EXPOSURE TO BEAM Avoid direct eye contac...

Page 7: ...t as stated on the left Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the projector is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the projector wi...

Page 8: ... and property Connection with the mains Connect the device to the mains with the power plug Always pay attention that the right color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make sure that the device is always connected properly to the earth ...

Page 9: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier upon receipt of m...

Page 10: ...Light source 12 x 0 5W LED Laser Power 130mW 100mW 650nm Red 30mW 532nm Green Control Modes DMX 512 Built in Programs Master Slave Sound controlled IR remote controlled Divergence each beam 2 mrad Divergence total light 160 degrees 3 pin DMX In and 3 pin DMX Out Clear red LED display for all settings Compact strong metal housing Sound controlled via built in microphone 2 and 11 DMX channel modes S...

Page 11: ...al connector OUT 09 3 pin DMX signal connector IN 10 LED Display LED indicators control buttons 11 Sound sensitivity control 12 Ground earth connection 13 IEC Power connector AC 100 240V OUT 14 IEC Power connector AC 100 240V IN Fuse 1 6AL 250V 15 Interlock 16 Remote control plug ...

Page 12: ...n Remove all packing materials from the X Terminator Check if all foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warranty Set Up and Operation Follow the directions below as they pert...

Page 13: ...lowed The interlock plug should be placed on the backside 16 of your X Terminator laser The keys should be put into the lock 15 of your X Terminator laser Warning Exclusion of liability Be aware that in some countries there are additional regulations regarding the use of laser devices Therefore we strongly advise you to verify your national laws with your authorities We do not take any responsibil...

Page 14: ...upply socket 04 When the X Terminator is not connected with a DMX cable it functions as a stand alone device 05 Please see page 18 for more information about the Sound controlled mode Multiple X Terminators Master Slave Mode 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Always use a safety cable ordercode 70140 70141 03 Plug the end of t...

Page 15: ...evices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units 06 Supply electric power Plug electric mains power cords into each unit s IEC socket then plug the other end of the mains power cord into proper electric power supply sockets starting with the first ...

Page 16: ...igital DMX signal Maximum recommended DMX data link distance 100 meters Maximum recommended number of fixtures on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can car...

Page 17: ...se make sure that you do not have any overlapping channels in order to control each X Terminator correctly If two or more X Terminators are addressed similarly they will work similarly Controlling After having addressed all X Terminator fixtures you may now start operating these via your lighting controller Note After switching on the X Terminator will automatically detect whether DMX 512 data is ...

Page 18: ...17 Ordercode 43157 X Terminator Menu Overview ...

Page 19: ...tons to run one of the sound controlled shows 04 Turn the control 11 on the rear panel to the left or right to respectively decrease or increase sensitivity of the device to background music 3 Master Slave Mode 01 Press the MODE button until the display shows 02 Press the ENTER button will appear on the display 03 The laser is now operating in Slave mode and it will react the same as the master de...

Page 20: ...he ENTER button to enter the menu 06 will appear shortly on the display 07 When it disappears the device will return to the previously active mode and the settings will be reset to the factory values If the display shows press the ENTER button to enter the menu 08 It is now possible to test if all the features available on the device work properly 09 It is possible to use the included remote contr...

Page 21: ...ens A 0 4 Off 5 127 Clockwise rotation from slow to fast 128 133 Stop 134 255 Counterclockwise rotation from slow to fast Channel 4 Color Lens B 0 24 Off 25 49 Blue 50 74 Amber 75 99 White 100 124 Blue Amber 125 149 Blue White 150 174 Amber White 175 199 Blue White Amber 200 224 Color switch 225 255 Color flow Channel 5 Strobe Effect Lens B 0 9 Off 10 254 Strobe speed from slow to fast Ch1 must be...

Page 22: ...ram 3 from slow to fast 40 49 Program 4 from slow to fast 50 59 Program 5 from slow to fast 60 69 Program 6 from slow to fast 70 79 Program 7 from slow to fast 80 89 Program 8 from slow to fast 90 99 Program 9 from slow to fast 100 109 Program 10 from slow to fast 110 119 Program 11 from slow to fast 120 129 Program 12 from slow to fast 130 139 Program 13 from slow to fast 140 149 Program 14 from ...

Page 23: ... this happens follow the directions below 01 Unplug the unit from electric power source 02 Insert a screwdriver into the slot in the fuse cover Gently pry up the fuse cover The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specif...

Page 24: ...s Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal operation is regained unplug both connectors and connect them directly together Have the defect...

Page 25: ... White and Amber Laser Color Red and Green Strobe 0 30Hz Cooling Cooling fans and TE Cooling Beam diameter 5mm at aperture Pulse Data All Pulses 4Hz 0 25 sec Divergence each beam 2 mrad Divergence total light 160 degrees Safety Features Key switch Interlock DMX control Via standard DMX controller Control Modes DMX 512 Built in Programs Master Slave Sound controlled IR Remote mode Housing Black Met...

Page 26: ...25 Ordercode 43157 X Terminator Dimensions ...

Page 27: ...26 Ordercode 43157 X Terminator ...

Page 28: ... 2016 Showtec ...

Reviews: