Ordercode: 43518 

Spectral 260 White 

 

DMX Modes 

 
The Spectral has 4 different DMX modes, see below. 
 

DIP Switches ON 

Function 

 

 

 
 
2 CHANNELS (STD.W) 
 

 

 

 
 
2 CHANNELS (STD.1) 
 

 

 

 
 
3 CHANNELS (STD.D) 
 

 

 

 
 
5 CHANNELS (S1.DS) 
 

 
 

 

Summary of Contents for spectral 260 white

Page 1: ...Spectral 260 White V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 43518 MANUAL ENGLISH ...

Page 2: ... 7 One Spectral Auto Built in programs 7 One Spectral Static colors 8 Multiple Spectrals Master Slave control 9 Multiple Spectrals DMX512 Mode 10 Dipswitch setting for DMX mode 11 DMX Address Quick Reference chart 12 Fixture Linking 13 Data Cabling 13 DMX Modes 14 DMX Configurations 15 2 Channels STD W 15 2 Channels STD 1 15 3 Channels STD D 15 5 Channels S1 DS 15 Maintenance 16 Troubleshooting 16...

Page 3: ...at their fullest intensity life of the LEDs is significantly reduced If improving the lifespan is of higher priority place care in providing for lower operational temperatures This may include climatic environmental and the reduction of overall projection intensity Safety Instructions Every person involved with the installation operation and maintenance of this device has to be qualified follow th...

Page 4: ...when device is not used or before cleaning Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the power cord from time to time I...

Page 5: ...ty of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carried out by an authorized dealer Procedure If the Spectral is lowered from the ceiling or high joists professional trussing systems have to be used Use a clamp to mount the Spectral with the mounti...

Page 6: ...proper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your address 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible def...

Page 7: ...X Dipswitches for Auto Static and DMX control Program 4 different DMX Operating modes Control protocol DMX 512 2 2 3 or 5 DMX channels Fixture connections XLR Data in out XLR 3 pin Schuko power cable Control Auto Static colors Master Slave DMX 512 Cooling Convection no fans Housing Die cast aluminum powder coated finish Bracket Double bracket function which can also be used as a floor stand Dimens...

Page 8: ...ower supply matches the product specification voltage Do not attempt to operate a 120V specification product on 230V power or vice versa Connect the device to the main power supply Control Modes There are 4 modes Auto Built in programs Static Colors manual Master Slave DMX512 2 2 3 or 5 Channels One Spectral Auto Built in programs 01 Fasten the effect light onto firm trussing Leave at least 0 5 me...

Page 9: ...e 12 Example Program 2 One Spectral Static colors 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use the safety cable which is included 03 When the Spectral is not connected by a DMX cable it functions as a stand alone device Dipswitch 10 and 12 must always be set to ON for Static colors control 04 Use dipswitch 1 4 to set the luminous in...

Page 10: ...at this process to link the second third and fourth units Dipswitch 10 must always be set to ON for Slave control You can use the same functions on the master device as described on page 7 8 Auto and Static colors This means you can set your desired operation mode on the master device and all slave devices will react the same as the master device Master control Auto programs Dipswitch 12 should be...

Page 11: ...se a 3 p XLR cable to connect the Spectral and other devices 05 Link the units as shown in Fig 04 Connect a DMX signal cable from the first unit s DMX out socket to the second unit s in socket Repeat this process to link the second third and fourth units Dipswitch 10 should be OFF 06 Do not supply power before the whole system is set up and connected properly Design your show according to your DMX...

Page 12: ...ue 1 1 2 2 3 4 4 8 5 16 Total sum 31 Explanation Since each unit has 5 channels each address advances 5 values See Address Value above Once address values are determined add DMX dip switch values to obtain the appropriate address DMX Dip Switches ON for each unit Flip appropriate DMX dip switches on each unit Example 01 If you want to give a Spectral DMX address 133 you first have to find the numb...

Page 13: ...12 Ordercode 43518 Spectral 260 White DMX Address Quick Reference chart ...

Page 14: ... must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a high quality signal and are less prone to electromagnetic interference DAP Audio DMX Data Cables DAP Audio Basic microphone cable for allround use bal XLR M 3 pin XLR F 3 pin Orde...

Page 15: ...14 Ordercode 43518 Spectral 260 White DMX Modes The Spectral has 4 different DMX modes see below DIP Switches ON Function 2 CHANNELS STD W 2 CHANNELS STD 1 3 CHANNELS STD D 5 CHANNELS S1 DS ...

Page 16: ...to brightest Channel 2 Warm white Dimmer must be open 0 255 Gradual adjustment Warm white from 0 100 Channel 3 Cool white Dimmer must be open 0 255 Gradual adjustment Cool white from 0 100 5 Channels S1 DS Channel 1 Dimmer intensity 0 255 From black to brightest Channel 2 Warm white Dimmer must be open 0 255 Gradual adjustment Warm white from 0 100 Channel 3 Cool white Dimmer must be open 0 255 Gr...

Page 17: ...erse in liquid Keep connections clean Disconnect electric power and then wipe the DMX and audio connections with a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Troubleshooting No Light This troubleshooting guide is meant to help solve simple problems If a problem occurs follow the steps below in sequence until a solution is found Once the...

Page 18: ...ion Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in output jack of the last fixture on the link Incorrect addressing of the fixtures Check address setting One of the fixtures is defective and disturbs data transmission on the link Bypass one fixture at a time until normal oper...

Page 19: ...nd 3x Cool white LEDs Output Lumen 160 Output Lux 2 meter 2600 Beam Angle 35 Max distance 10 meter Dimmer 0 100 Strobe 0 20Hz Housing Die cast aluminum powder coat finish Bracket Double bracket function which can also be used as a floor stand Onboard DMX Dipswitches for Auto Static and DMX control Control Auto Static Slave DMX Connections Special XLR Data in out XLR 3 pin Schuko power cable Coolin...

Page 20: ...19 Ordercode 43518 Spectral 260 White Dimensions ...