background image

 

  

 

 

30 

   

 

Ordercode: 33038 

Performer 2000 RGBAL 

Channel 11 – Lime 

 CH1 must be open; CH13-14 must be closed 

 

0-255 

Gradual adjustment Lime, from 0-100% 

 

Channel 12 – Fine Lime 

 CH1 and CH11 must be open; CH13-14 must be closed 

 

0-255 

Fine adjustment Lime, from 0-100% 

 

Channel 13 – Color presets 

 CH1 must be open 

 

0-10 

Not functional 

11-20 

L106 

21-30 

R05 

31-40 

L194 

41-50 

R54 

51-60 

L019 

61-70 

R08 

71-80 

R89 

81-90 

R86 

91-100 

L213 

101-110 

R377 

111-120 

R80 

121-130 

L202 

131-140 

L328 

141-150 

R3314 

151-160 

L101 

161-170 

L768 

171-255 

Not functional 

 

Channel 14 – Macros 

 CH1 must be open 

 

0-10 

Not functional 

11-30 

Red 100% / Green Up / Blue 0% 

31-50 

Red Down / Green 100% / Blue 0% 

51-70 

Red 0% / Green 100% / Blue Up 

71-90 

Red 0% / Green Down / Blue 100% 

91-110 

Red Up / Green 0% / Blue 100% 

111-130 

Red 100% / Green 0% / Blue Down 

131-150 

Red 100% / Green Up / Blue Up 

151-170 

Red Down / Green Down / Blue 100% 

171-195 

Red 100% / Green 100% / Blue 100% / White 100% 

196-200 

2700K 

201-205 

3000K 

206-210 

3200K 

211-215 

3500K 

216-220 

4000K 

221-225 

4200K 

226-230 

4500K 

231-235 

5600K 

236-240 

6000K 

241-245 

6500K 

246-250 

7200K 

251-255 

8000K 

 
 

 

Summary of Contents for Performer 2000 RGBAL

Page 1: ...Performer 2000 RGBAL V2 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 33038 MANUAL ENGLISH...

Page 2: ...le Performers DMX Control 12 Fixture Linking 13 Data Cabling 13 Control Panel 14 Control Mode 14 DMX Addressing 14 Menu Overview 15 Main Menu Options 16 1 Manual Mode 16 1 1 Mode 1 17 1 2 Mode 2 17 1...

Page 3: ...8 channels HSIC 25 10 channels SSP 26 13 channels TOUR 27 19 channels TR16 29 Cleaning 31 Cleaning the Glass Lens 31 Maintenance 32 Replacing the Fuse 32 Troubleshooting 32 No Light 32 No Response to...

Page 4: ...s Showtec Performer 2000 RGBAL Pro power cable 1 5 m 1 x safety cable User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acc...

Page 5: ...losed and all screws are tightly fastened Only operate the device after having familiarized with its functions Avoid flames and do not put close to flammable liquids or gases Always keep the case clos...

Page 6: ...dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing...

Page 7: ...ght color cable is connected to the right place International EU Cable UK Cable US Cable Pin L BROWN RED YELLOW COPPER PHASE N BLUE BLACK SILVER NEUTRAL YELLOW GREEN GREEN GREEN PROTECTIVE GROUND Make...

Page 8: ...number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this c...

Page 9: ...100 Dimming curves Dimm4 technology 4 presets Dimmer resolution 16bit Strobe 0 25Hz Control protocol RDM DMX 512 DMX channels 8 10 13 19 channels Motorized zoom 15 45 Field angle 25 76 Control modes S...

Page 10: ...foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning o...

Page 11: ...ng clip before hanging the Performer 2000 RGBAL 01 Release the retaining clip by pressing the lock towards the lens and pressing the longer side of the screw The retaining clip will open 02 Insert the...

Page 12: ...Performers Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin 5 pin XLR cable to connect the Performer The pin...

Page 13: ...Connect the first unit s DMX out socket with the second unit s in socket using a DMX signal cable Repeat this process to link the second third and fourth units 05 Supply electric power Plug electric m...

Page 14: ...ures on a power link 230V 8 fixtures Data Cabling To link fixtures together you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct...

Page 15: ...020 the DMX address of the third Performer should be 20 19 39 039 etc Please be sure that you do not have any overlapping channels in order to control each Performer correctly If two or more Performe...

Page 16: ...15 Ordercode 33038 Performer 2000 RGBAL Menu Overview...

Page 17: ...gle through the 10 main menu options 04 Press the ENTER button to open the desired submenu 1 Manual Mode In this menu you can set and adjust the desired manual mode 01 While in main menu press the UP...

Page 18: ...Mode 2 In this menu you can set the dimmer zoom and choose a color preset 01 Turn the controls F G H to adjust settings 02 The adjustment ranges are F Dimmer 0 100 from dark to brightest G Zoom 0 100...

Page 19: ...s STATIC 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to toggle through the 7 options RED 0 255 from dark to brightest GREEN 0 255 from dark to brightest BLUE 0 255 from dar...

Page 20: ...Press the UP DOWN buttons to toggle through the 16 color presets L106 R05 L194 R54 L019 R08 R89 R86 L213 R377 R80 L202 L328 R3314 L101 L768 4 Address In this menu you can set the desired DMX starting...

Page 21: ...el mode personality 01 While in main menu press the UP DOWN buttons until the display shows PERSONALITY 02 Press the ENTER button to open the menu 03 Press the UP DOWN buttons to toggle through the 4...

Page 22: ...o insert a key combination which will unlock this hidden menu To do so press the buttons in the following order UP DOWN UP DOWN ENTER 03 The device will now reset its settings 7 3 Color In this menu y...

Page 23: ...rformance of the cooling fan 01 When the display shows PERFORMANCE press the ENTER button to open the menu 02 Press the UP DOWN buttons to toggle through the 3 modes LIVE Default mode It provides a co...

Page 24: ...open the menu 02 Press the UP DOWN buttons to toggle through the 5 options 3200K 4200K 5600K 10000K NORMAL 8 Key In this menu you can set the safety lock 01 While in main menu press the UP DOWN butto...

Page 25: ...ENTER button to choose the desired color 05 Press the UP DOWN buttons to increase decrease the intensity of the chosen color The adjustment range of each color is between 0 255 from OFF to FULL ON 06...

Page 26: ...een UID and LABEL 02 Press the ENTER button to view the desired RDM menu DMX Channels 8 channels HSIC Channel 1 Dimmer intensity 0 255 Gradual adjustment from dark to brightest 0 100 Channel 2 Hue col...

Page 27: ...inear dimmer 3 190 255 Non linear dimmer 4 slowest 10 channels SSP Channel 1 Dimmer intensity 0 255 Gradual adjustment from dark to brightest 0 100 Channel 2 Red CH1 must be open CH7 must be closed 0...

Page 28: ...0 69 Non linear dimmer 1 fastest 70 129 Non linear dimmer 2 130 189 Non linear dimmer 3 190 255 Non linear dimmer 4 slowest 13 channels TOUR Channel 1 Dimmer intensity 0 255 Gradual adjustment from da...

Page 29: ...1 170 Red Down Green Down Blue 100 171 195 Red 100 Green 100 Blue 100 White 100 196 200 2700K 201 205 3000K 206 210 3200K 211 215 3500K 216 220 4000K 221 225 4200K 226 230 4500K 231 235 5600K 236 240...

Page 30: ...from dark to brightest 0 100 Channel 3 Red CH1 must be open CH13 14 must be closed 0 255 Gradual adjustment Red from 0 100 Channel 4 Fine Red CH1 and CH3 must be open CH13 14 must be closed 0 255 Fine...

Page 31: ...0 R80 121 130 L202 131 140 L328 141 150 R3314 151 160 L101 161 170 L768 171 255 Not functional Channel 14 Macros CH1 must be open 0 10 Not functional 11 30 Red 100 Green Up Blue 0 31 50 Red Down Green...

Page 32: ...fast Channel 19 Dimmer speed 0 9 Preset dimmer speed from the device s menu 10 29 Linear dimmer 30 69 Non linear dimmer 1 fastest 70 129 Non linear dimmer 2 130 189 Non linear dimmer 3 190 255 Non lin...

Page 33: ...h a damp cloth Make sure connections are thoroughly dry before linking equipment or supplying electric power Replacing the Fuse Power surges short circuit or inappropriate electrical power supply may...

Page 34: ...all to the controller Poor data quality Check data quality If much lower than 100 percent the problem may be a bad data link connection poor quality or broken cables missing termination plug or a defe...

Page 35: ...Dimming curves Dimm4 technology 4 presets Dimmer resolution 16bit Strobe 0 25Hz Peak intensity 41900cd Color rendering 90Ra 2700 4500K 85Ra 5600 8000K Color temperature 2700 8000K Refresh rate 600Hz t...

Page 36: ...35 Ordercode 33038 Performer 2000 RGBAL Dimensions...

Page 37: ...36 Ordercode 33038 Performer 2000 RGBAL Notes...

Page 38: ...37 Ordercode 33038 Performer 2000 RGBAL...

Page 39: ...38 Ordercode 33038 Performer 2000 RGBAL...

Page 40: ...2017 Showtec...

Reviews: