background image

 

Installation 

Remove all packing materials from the 

LED Design Par

. Check that all foam and plastic padding is 

removed. Connect all cables. 
 

Do not supply power before the whole system is set up and connected properly.

 

Always disconnect from electric mains power supply before cleaning or servicing. 
Damages caused by non-observance are not subject to warranty.

 

 

 

Set Up and Operation 

Before plugging the unit in, always make sure that the power supply matches the product specification 
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.

 

 

Fixture Linking

 

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to 
run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined 
number of channels required by all the fixtures on a serial data link determines the number of fixtures the 
data link can support.  
 
The LED Design Par uses 9 channels. 
 

Important:

  

Fixtures on a serial data link must be daisy chained in one single line. To comply with the  
EIA-485 standard no more than 30 devices should be connected on one data link. 
Connecting more than 30 fixtures on one serial data link without the use of a DMX optically 
isolated splitter may result in deterioration of the digital DMX signal. 
 
Maximum recommended DMX data link distance: 100 meters 
Maximum recommended number of LED Pars on a DMX data link: 30 fixtures 
@ 220V: 40 units may be connected in series 
@120V: 20 units may be connected in series 

 

Data Cabling

 

To link fixtures together you must obtain data cables. You can purchase DAP Audio certified DMX cables 
directly from a dealer/distributor or construct your own cable. If you choose to create your own cable 
please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic 
interference. 
 

DAP Audio Certified DMX Data Cables 

• DAP Audio Basic microphone cable for allround use. 

bal. XLR/M 3 p. > XLR/F 3 p.  

   Ordercode

 FL01150 (1,5m.), FL013 (3m.), FL016 (6m.), FL0110 (10m.), FL0115 (15m.), FL0120 (20m.). 

• DAP Audio cable f

or the demanding user with exceptional audio-qualities and connector made by  

    Neutrik®.

 Ordercode

 FL71150 (1,5m.), FL713 (3m.), FL716 (6m.), FL7110 (10m.). 

 

 

 
 
 
 
 
 
 
 

Summary of Contents for LED Design Par18 RGB

Page 1: ...LED Design Par 18 RGB ORDERCODE 42570...

Page 2: ...on Showtec for more excellent lighting products We design and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you...

Page 3: ...allation Set Up and Operation Fixture Linking Data Cabling Control Panel DMX Addressing without ID addressing DMX Addressing with ID Address MENU OVERVIEW Creating a static color Activating an Auto Pr...

Page 4: ...tures This may include climatic environmental and the reduction of overall projection intensity SAFETY INSTRUCTIONS Every person involved with the installation operation and maintenance of this device...

Page 5: ...o that its functions are not impaired due to cracks or deep scratches If device is dropped or struck disconnect mains power supply immediately Have a qualified engineer inspect for safety before opera...

Page 6: ...Par with the mounting bracket to the trussing system The LED Design Par must never be fixed swinging freely in the room The installation must always be secured with a safety attachment e g an appropri...

Page 7: ...ouble boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone numb...

Page 8: ...RGB color mixing with or without DMX controller Built in automated programs via master slave DMX Recall custom programs via master slave or DMX Menu settings LCD display Control DMX 512 High power 1W...

Page 9: ...view 1 2 3 Fig 1 1 18 x 1 Watt 6x Red 6x Green 6x Blue 2 Blinder 3 Mountingbracket for Truss mounting Bottom 4 6 5 7 Fig 2 4 IEC Power Out 5 IEC Power In 6 DMX signal connector OUT 7 DMX signal connec...

Page 10: ...ata link must be daisy chained in one single line To comply with the EIA 485 standard no more than 30 devices should be connected on one data link Connecting more than 30 fixtures on one serial data l...

Page 11: ...onnect a DMX controller example 50333 Scanmaster 2 MKII to the series of LED Design Pars 2 Each LED Design Par has 9 DMX channels DMX address LED Par 1 1 Par 2 10 Par 3 19 Par 4 28 etc 3 The ID addres...

Page 12: ...anmaster 2 MKII 50333 Example 1 The figure above shows a simple DMX layout All the LED Design Pars have different ID addresses which allows the user to collectively control the whole group of LED Desi...

Page 13: ...11 MENU OVERVIEW 9 channels 3 channels 4 channels...

Page 14: ...menu Use the UP DOWN buttons to change the static colors Red Green Blue or the strobe speed 0 20Hz Press MODE to go 1 step back You can combine RED GREEN and BLUE to create an infinite range of color...

Page 15: ...ENTER in menu Auto Program you can choose one of the 10 built in programs You can also edit 10 custom programs DMX 512 Address When you press ENTER in menu DMX 512 address you can set the DMX address...

Page 16: ...he RUN MODE does not work Personality Enter the PERSONALITY mode to select DMX mode STAGE 1 ARC 1 ARC 1 D STAGE 1 9 channels ARC 1 3 channels ARC 1 D 4 channels ID Address Enter the ID ADDRESS mode to...

Page 17: ...ad custom programs from the current MASTER device to the SLAVE devices Activate Password Enter the KEY LOCK mode to select whether the access password is On or Off The Access Password UP DOWN UP DOWN...

Page 18: ...e Up Down to change the values Use Up Down to change the values Use Up Down to change the values Use Up Down to change the values Use Up Down to change the values And so you can add a maximum of 30 sc...

Page 19: ...p Red 0 Green Down Blue 100 Red Up Green 0 Blue 100 Red 100 Green 0 Blue Down Red 100 Green Up Blue Up Red Down Green Down Blue 100 White 1 3200K White 2 3400K White 3 4200K White 4 4900K White 5 5600...

Page 20: ...ty of the output is at its maximum RED GREEN AND BLUE SELECTION Channels 2 3 and 4 control the overall intensity of each respective color Channels 2 3 and 4 can be combined to create an unlimited rang...

Page 21: ...234 ID address 45 120 129 ID address 12 235 ID address 46 130 139 ID address 13 236 ID address 47 140 149 ID address 14 237 ID address 48 150 159 ID address 15 238 ID address 49 160 169 ID address 16...

Page 22: ...20 Beam Angles...

Page 23: ...ning as smoke fluid tends to build up residues reducing the light output very quickly Do not immerse in liquid Keep connections clean Disconnect electric power and then wipe the DMX connections with a...

Page 24: ...der where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product specification label for details Troubleshooting This troubleshooting guide i...

Page 25: ...ograms via master slave DMX Recall custom programs via master slave or DMX Menu settings LCD display Control DMX 512 High power 1W 350mA LEDs RGB color mixing with or without DMX controller Color temp...

Page 26: ......

Reviews: