26
Solaris 5.5 incl. FB4
Product code: 51363
6.
Operation
Safety Instructions for Operation
WARNING
Laser radiation
Avoid eye or skin exposure to direct or scattered radiation.
This device is a class 4 laser device according to the classification in NEN-EN-IEC 60825-1:2014. It emits
visible radiation in the wavelength range 400–700 nm. Exposure to the direct or scattered laser beam can
result in severe eye damage and serious skin injuries.
Check all applicable national and international regulations concerning laser safety before operating this
device.
Attention
This device must be used only for the purposes it is designed for.
This device is intended for professional use as a laser projector to produce laser displays or show effects. It
is suitable only for indoor installation. This device is not suitable for households.
Any other use, not mentioned under intended use, is regarded as non-intended and incorrect use.
Attention
Power supply
Before connecting the device to the power supply, make sure that the current, voltage and frequency
match the input voltage, current and frequency specified on the information label on the device.
Starting the Device
Make sure that all laser safety measures are in place and working. See 2.3. Laser Safety on page 10
for more information.
Connect all data cables, if applicable. See 5.3. Setup Example with One Device on page 21 and 5.4.
Setup Example with Multiple Devices on page 22 for more information.
Connect the remote interlock to one of the Ethernet & interlock RJ45 connectors (13)/(16) of the
device. See 5.5. Using the Safety Devices on page 23 for more information.
Connect the device to the socket-outlet with the power plug. See. 4.5. Connecting to Power Supply
on page 18 for more information.
Set the power switch (21) in ON position. The device is powered.
Insert the keys into the key switch (15) on the device and the key switch (31) on the remote interlock.
The device is now operational.
Turn the key switch (15) of the device and the key switch (31) of the remote interlock in ON position
to turn on the laser beam. See 5.5. Using the Safety Devices on page 23 for more information. The
status LED indicator (14) starts blinking. The laser emission begins 10 seconds after the laser beam is
turned on. The status LED indicator (14) and the laser emission LED indicator (10) light up during laser
emission.
Note: