background image

 

  

 

 

   

 

Order code: 50705 

ColorCue 3 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the 

fixture. Be prepared to provide the model number, serial number and a brief description of the cause for 
the return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is 
the customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 
Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 
01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery.  
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 
 

 

Summary of Contents for 50705

Page 1: ...ColorCue 3 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 50705 MANUAL ENGLISH...

Page 2: ...Selection Mode vs Parameter Selection Mode 10 Strobe 10 Blackout 10 Flash 10 Hold 10 Clear the Programmer 11 Manual Operating Mode 11 Create a Scene in Bank A Double Control Mode 11 Create a Scene in...

Page 3: ...udes Showtec ColorCue 3 AC power adapter with 4 interchangeable AC plugs Europe UK US JP AUS NZ User manual Safety Instructions Every person involved with the installation operation and maintenance of...

Page 4: ...upply immediately Have a qualified engineer inspect for safety before operating If the device has been exposed to drastic temperature fluctuation e g after transportation do not switch it on immediate...

Page 5: ...umber 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this ch...

Page 6: ...channels 6 DMX channels per fixture MIDI Yes Memories 1000 Display LCD Connections 3 pin DMX signal connector OUT USB input connector no function DC input connector 5 pin MIDI connectors THRU OUT IN...

Page 7: ...ntrol D Modes buttons with LEDs J UV control E RED DIRECTION control K BANK A master fader and flash button with LED F GREEN SPEED control L BANK B master fader and flash button with LED G BLUE FADE c...

Page 8: ...troller to a power outlet with the supplied AC power adapter Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not subject to warrant...

Page 9: ...enter setup mode The LED on the button will start blinking Refer to LEDs Type Setup on page 8 and to MIDI Address Setup on page 9 for more information about the available settings in this mode 02 Pres...

Page 10: ...ll display the correct starting DMX address of each fixture Approach 2 If you select all fixtures first and then set the LEDs type only the starting DMX address of the last fixture will be displayed o...

Page 11: ...tically disables the other mode The UV control J does not have a double function It functions only in color selection mode Strobe You can add strobe effect at any time during playback of a scene or a...

Page 12: ...ed in step 2 The LEDs above the fixtures faders will light up 04 Make sure the color selection mode is enabled Turn the controls E J to select the desired color The available colors are red green blue...

Page 13: ...ture s you want to control The LED s on the button s will light up If you want to have the same color for all connected fixtures press all FIXTURES buttons 01 24 If you want to have different colors f...

Page 14: ...f a PLAYBACKS button 01 24 is not free and has a scene assigned to it the LED on the button will be on 04 Press the RECORD button 36 once again to store the scene The LED on the button will turn off 0...

Page 15: ...on Turn the DIRECTION control E to set the direction of the chase There are 3 options available Off position the chase will play back in reverse order The direction of the chase will be displayed on t...

Page 16: ...chase The LED on the button will start blinking The PLAYBACKS button number will be displayed on the screen Note At this point you can also adjust the chase parameters direction speed and fade Make s...

Page 17: ...nly with the FIXTURES buttons and faders 01 12 Single 24 fixture mode follow steps 2 6 from Create a Scene on page 12 06 Press the UPDATE button 42 to insert the new step The LED on the UPDATE button...

Page 18: ...e LED s above the fader s will light up and the selected chase s will be played back The LED s on the respective PLAYBACKS button s 01 24 are blinking during playback During playback you can add strob...

Page 19: ...uence until a solution is found Once the unit operates properly do not carry out following steps No Light If the ColorCue 3 does not operate properly refer servicing to a technician Suspect three pote...

Page 20: ...s 24 Fixture channels 6 DMX channels per fixture Playback keys 24 Playback faders 24 MIDI Yes Display LCD Connections 3 pin DMX signal connector OUT USB input connector no function DC input connector...

Page 21: ...20 Order code 50705 ColorCue 3 Dimensions...

Page 22: ...s OFF X X Active Sense X X Reset X X O YES Mode 1 OMNI ON POLY Mode 2 OMNI ON MONO X NO Mode 3 OMNI OFF POLY Mode 4 OMNI OFF MONO 1 table 1 note numbers note number function 22 45 16H 2DH Channel 1 24...

Page 23: ...22 Order code 50705 ColorCue 3...

Page 24: ...2020 Showtec...

Reviews: