24
Spectral M800 Q4 IP
Product code: 43571
DMX Linking
To connect multiple devices on one DMX data link, follow the steps below:
Use a 3-pin DMX cable to connect the DMX OUT connector of the lighting controller to the DMX IN
connector of the first device.
02)
Connect the first device’s DMX OUT connector to the second device’s DMX IN connector with a
3-pin DMX cable.
03)
Repeat step 2 to connect all devices in a daisy-chain as shown in Fig. 14.
04)
Connect a DMX terminator (120 Ω resistor) to the DMX OUT connector of the last device on the data
link.
Fig. 14
DMX Addressing
In a setup with multiple devices, make sure that you set the DMX starting address of each device
correctly. The Spectral M800 Q4 IP has 9 personalities: 4 channels, 4 channels, 5 channels, 6 channels, 7
channels, 9 channels, 10 channels, 13 channels and 15 channels.
If you want to connect multiple devices on one data link and use them in 15-channel mode, for
example, follow the steps below:
01)
Set the starting address of the 1
st
device on the data link to 1 (001).
02)
Set the starting address of the 2
nd
device on the data link to 16 (016), as 1 + 15 = 16.
03)
Set the starting address of the 3
rd
device on the data link to 31 (031) as 16 + 15 = 31.
04)
Continue assigning the starting addresses of the remaining devices by adding each time 15 to the
previous number.
Make sure that you do not have any overlapping channels in order to control each Spectral M800 Q4 IP