background image

 

  

 

 

   

 

Ordercode: 42685 

Cameleon Bar 24/1 UV 

 

 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light output and the illuminated surface must be bigger than 1 
meter. 

 

The maximum ambient temperature t

a

 = 40°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 40° C. 

 

If this device is operated in any other way than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 

You endanger your own safety and the safety of others! 

 
 

Rigging 

Please follow the European and national guidelines concerning rigging, trussing and all 
other safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the projector is lowered from the ceiling or high joists, professional trussing systems have to be used. 

 

Use a clamp to mount the projector, with the mounting bracket, to the trussing system. 

 

The projector must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net or 
safety cable. 

 

When rigging, derigging or servicing the projector, always make sure, that the area below the 
installation site is secured and that there are not any unauthorized people around. 

 

 

 
The Cameleon Bar 24/1 UV can be placed on a flat stage floor or be mounted to a wall. 
 

Improper installation can cause serious injuries and/or damage of property! 

 

 

Summary of Contents for 42685

Page 1: ...Cameleon Bar 24 1 UV V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42685 MANUAL ENGLISH...

Page 2: ...Modes 8 One Cameleon Auto mode and Manual 8 Multiple Cameleons Master Slave control 8 Multiple Cameleons DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressi...

Page 3: ...xpected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatur...

Page 4: ...flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a free air space of at least 50 cm around the unit for ventilation Always disconnect...

Page 5: ...others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carrie...

Page 6: ...oper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your ad...

Page 7: ...Manual mode Master Slave DMX 512 Metal flame retardant plastic housing Dimmer 0 100 Strobe 0 20Hz Connections Dedicated IP65 power connector IN OUT Special 3 pin XLR IN OUT IP rating IP65 Dimensions 1...

Page 8: ...s Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not...

Page 9: ...ameleons Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the Cameleon The pins 01 Earth...

Page 10: ...the 42708 DMX input cable Connect the first unit s out socket with the second unit s in socket using the 42707 DMX Extension cable Link the second third and fourth units using the 42707 DMX Extension...

Page 11: ...ther you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data g...

Page 12: ...the third Cameleon should be 6 5 11 011 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon correctly If two or more Cameleons are addressed similarly th...

Page 13: ...the MODE button for 2 seconds until the display shows 02 Press the MODE button once to open the menu 03 Press the UP DOWN buttons to increase decrease the program speed The adjustment range is between...

Page 14: ...le in the main menu press and hold down the MODE button for 2 seconds until the display shows 02 Repeatedly press the MODE button to move the radix point in order to choose the digit which you want to...

Page 15: ...The following points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may...

Page 16: ...to your Showtec dealer 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Cameleon as this may damage the unit a...

Page 17: ...disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert term...

Page 18: ...4 Maximum distance 10 m Color mixing UV Dimmer 0 100 Strobe 0 20Hz Beam angle 25 Housing Metal Flame retardant plastic DMX control via standard DMX controller Onboard LED display for easy setup Contro...

Page 19: ...18 Ordercode 42685 Cameleon Bar 24 1 UV Dimensions...

Page 20: ...2015 Showtec...

Reviews: