background image

 

  

 

 

   

 

Ordercode: 42685 

Cameleon Bar 24/1 UV 

To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes contained in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device.

 

 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never lift the fixture holding it by the projector-head, as the mechanics may be damaged. Always 
hold the fixture by the transport handles. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not insert objects into air vents. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the case closed while operating. 

 

Always allow a free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The fixture must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

The user is responsible for correct positioning and operating of the Cameleon. The manufacturer will 
not accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

Summary of Contents for 42685

Page 1: ...Cameleon Bar 24 1 UV V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 42685 MANUAL ENGLISH...

Page 2: ...Modes 8 One Cameleon Auto mode and Manual 8 Multiple Cameleons Master Slave control 8 Multiple Cameleons DMX Control 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Control Mode 11 DMX Addressi...

Page 3: ...xpected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the acceleration of this decline Packaged in clusters LEDs exhibit higher operating temperatur...

Page 4: ...flames and do not put close to flammable liquids or gases Always keep the case closed while operating Always allow a free air space of at least 50 cm around the unit for ventilation Always disconnect...

Page 5: ...others Rigging Please follow the European and national guidelines concerning rigging trussing and all other safety issues Do not attempt the installation yourself Always let the installation be carrie...

Page 6: ...oper UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your ad...

Page 7: ...Manual mode Master Slave DMX 512 Metal flame retardant plastic housing Dimmer 0 100 Strobe 0 20Hz Connections Dedicated IP65 power connector IN OUT Special 3 pin XLR IN OUT IP rating IP65 Dimensions 1...

Page 8: ...s Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleaning or servicing Damages caused by non observance are not...

Page 9: ...ameleons Master Slave control 01 Fasten the effect light onto firm trussing Leave at least 0 5 meter on all sides for air circulation 02 Use a 3 pin XLR cable to connect the Cameleon The pins 01 Earth...

Page 10: ...the 42708 DMX input cable Connect the first unit s out socket with the second unit s in socket using the 42707 DMX Extension cable Link the second third and fourth units using the 42707 DMX Extension...

Page 11: ...ther you must obtain data cables You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data g...

Page 12: ...the third Cameleon should be 6 5 11 011 etc Please be sure that you do not have any overlapping channels in order to control each Cameleon correctly If two or more Cameleons are addressed similarly th...

Page 13: ...the MODE button for 2 seconds until the display shows 02 Press the MODE button once to open the menu 03 Press the UP DOWN buttons to increase decrease the program speed The adjustment range is between...

Page 14: ...le in the main menu press and hold down the MODE button for 2 seconds until the display shows 02 Repeatedly press the MODE button to move the radix point in order to choose the digit which you want to...

Page 15: ...The following points have to be considered during the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may...

Page 16: ...to your Showtec dealer 04 If all of the above appears to be O K plug the unit in again 05 If you are unable to determine the cause of the problem do not open the Cameleon as this may damage the unit a...

Page 17: ...disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert term...

Page 18: ...4 Maximum distance 10 m Color mixing UV Dimmer 0 100 Strobe 0 20Hz Beam angle 25 Housing Metal Flame retardant plastic DMX control via standard DMX controller Onboard LED display for easy setup Contro...

Page 19: ...18 Ordercode 42685 Cameleon Bar 24 1 UV Dimensions...

Page 20: ...2015 Showtec...