Malfunction Causes and Measures 

Fan malfunction causes and measures 

 

 
 

Malfunction status 

 
 
 
 
 
Malfunction cause 

Overs and sho

rts of quantity 

of wind, the sta

tic pressure

 

Excess/short of motor 

Beari

ng ov

erhe

at/burno

ut 

 

Abnorm

al vibr

a

tion

 

Pecul

iar no

ise

 

Corrosi

on a

nd 

wear

 

Abnorm

al cont

act 

Motor not activated 

Measures 

Defective installation 

 

 

 

 

 

 

 

 Re-installation 

Poor foundation 

 

 

 

 

 

 

 

 

Renovation 

Contact with the rotator? 

 

 

 

 

 

 

 

 

Processing of contact part, 
and re-installation 

Defective duct/duct joint 

 

 

 

 

 

 

 

 Renovation 

Defective lubricating oil 

 

 

      

Replenishment 

Inappropriate oil quality, 
contamination, excessive 
amount of oil 

 

 

      

Replacement 

or 

recycling 

 

Inappropriate material 

 

 

 

 

 

    

Replacement 

Unbalanced impeller 

 

 

 

 

 

 

  

Correction 

Deformation or damage of 
impeller 

 

 

 

     

Repair 

or 

replacement 

Wear or corrosion of impeller 

 

 

 

 

 

 

 

 

Repair or replacement 

Operation at a dangerous speed 

 

 

 

 

 

 

 

 

Renovation or remodeling 
of operation point 

Abnormal bearing of the motor 

 

 

 

 

    

Replacement 

Wrong rotation direction 

 

 

 

 

 

 

 

 Change 

Malfunction of the motor 

 

 

 

 

 

 

 

 

Repair or replacement 

Intake of light gas 

 

 

 

 

 

 

 

 

Renovation/replacement of 
impeller 

Intake of heavy gas 

 

 

 

 

 

 

 

 

Renovation/replacement of 
impeller 

Mixture of foreign object or 
adhesion of scale 

 

 

 

 

 

 

 

 Cleaning 

Surging operation 

 

 

 

 

 

 

 

 

Change of operation point 

Resistance to the pipe system   

 

 

 

 

 

 

 

 

Renovation 

Failure of damper 

 

 

 

 

 

 

 

 Repair 

Accumulation in the drain 

 

 

 

 

 

 

 

 Draining 

There is less pressure loss than 
a plan 

 

 

 

 

 

 

 

 

Damper adjustment, 
change of the rotary speed 

Summary of Contents for MAA1050-Y005E

Page 1: ...MAA1050 Y005E Blower Operating Instructions Axial Flow Mixed Flow Type Blower...

Page 2: ...ification of the V belt drive blower blower in which a motor pulley and V belt are incorporated Only the main body of the motor shaft direct coupling blower impeller is an accessory These Operating In...

Page 3: ...stallation 8 4 1 Installation 8 4 2 Duct connection 9 4 3 Installation of the motor when the blower adopts the specification of V belt drive main body only 10 4 4 Test operation 12 5 Operation 13 5 1...

Page 4: ...rush out This may cause a serious accident Keep your face away from around the discharge port Small dust etc taken in by the blower may rush out of the discharge port at a high speed If such dust ente...

Page 5: ...xtension rules Also refer to the Operating Instructions of the motor Before starting test operation confirm that nothing is left in the connected duct or casing or near the intake port discharge port...

Page 6: ...mercial inverter is not suitable for the blower Change the following values at least Base frequency Adjust to the rated frequency of the blower 50 Hz or 60 Hz Highest frequency Adjust to the rated fre...

Page 7: ...table below The model is indicated on the product nameplate nameplate affixed to the side face of the blower main body casing A V 5 K M Blank Main body only M With a motor Blank Motor shaft direct cou...

Page 8: ...n the case of the specification of main body only none of the motor pulley on the motor side and V belt are attached to the blower V belt drive Motor shaft direct coupling Normal temperature specifica...

Page 9: ...manually carefully prevent the hand from being caught 4 Installation 4 1 Installation 4 1 1 Selection of installation location Install the blower in a location as shown below A location at a normal te...

Page 10: ...t resulting in damage to the product When installing the duct pay attention to the following points 1 When using a flexible joint apply appropriate tension to it Keep the length to the minimum necessa...

Page 11: ...ension of the belt use adjustment nuts to fix the motor base Procedure for tensing the belt Step 1 Span calculation First calculate the span of the V belt The span of the V belt is part of the connect...

Page 12: ...range of small diameter of 3V 5V type is indicated in nominal diameter A lack or excess of belt tension causes abnormal phenomena The following table indicates how to distinguish a lack of belt tensi...

Page 13: ...ally confirm the rotation direction Affix a seal to the main body to indicate the rotation direction If the blower rotates in the reverse direction it makes the air flow in the reverse direction If th...

Page 14: ...k the temperature near the bearing and any changes to it Electrical section Check the current value and voltage value and any changes to them Component inspection V belt Check the tension Check for we...

Page 15: ...specified grease Temperature specification of blower Grease manufacturer Product name of grease brand Normal temperature specification Showa Shell Sekiyu K K Albania S3 Heat proof specification Dow Co...

Page 16: ...aring type Repleni shment amount g Bearing type Repleni shment amount g Bearing type Repleni shment amount g Bearing type Replenis hment amount g Bearing type Replenis hment amount g UC203 204 205 206...

Page 17: ...efore the restart of operation make sure to perform an inspection similar to that for test operation In particular check for materials adhering to the impeller or for corrosion on it 6 About the rotar...

Page 18: ...actors such as salt damage and public pollution abnormal voltage use of a power supply voltage or frequency other than that specified or the like Failure or damage due to repair or modification includ...

Page 19: ...Replacement or recycling Inappropriate material Replacement Unbalanced impeller Correction Deformation or damage of impeller Repair or replacement Wear or corrosion of impeller Repair or replacement...

Page 20: ...purchased blower Fan identification information that you may need when making an inquiry of us TYPE SERIAL NO Date of Purchase Year Month Day Date of start of operation Year Month Day Supplier TEL Per...

Reviews: