35
1 - RS485 read and write address overview
RS485 Coding Setting
OK
Coding setting finished
Press and hold the setting
yey for 4 seconds and release
until beep sound × 2
RS485 equipment
RS485 sending out codes
RS485 equipment
The indication light of RS485 is off
Data address
Read / write
0x00
Write
0x01
0x03
Read / write
0x05
Read only
0x09
Read only
0x0A
Read / write
0xf1
Read only
0xfe
Read only
0x0C
Description
ID_L
ID_H
Motor default
direction
Motor status
Limit status
Touch and move
mode
Module channel
number
Protocol version
Power on
indication
Read / write
*
*
M
M
M
M
*
*
M
Data Format
0x00 - Default directiont
0x01 - Reverse directiont
0x00 - STOP
0x01 - OPEN
0x02 - CLOSE
0x03 - SETTING
Bit1 Limit Point Set 1
Bit2 Limit Point Set 2
Bit3 Limit Point Set 3
Bit4 Limit Point Set 4
0 - Off
1 - On
1-15
0xA4
0 - No indication
1 - Sound
2 - Movement
3 - Movement AND sound
Instructions
Description
Instruction parameters
Remarks
Move roller up
0x01
None
0x02
Move roller down
None
0x03
Stop command
None
0x05
Set the limit
1-4 - Set the upper limit point
22 - Set the lower limit point
23 - Set the 3rd limit
24 - Set the 4th limit
0x06
Run to the limit
point
1-4 - Run to the upper limit point 22 - Run to the lower limit point
23 - Run to the 3rd limit
24 - Run to the 4th limit
0x07
Delete the limits
None - Delete all
1-4 - Delete the upper limit point
22 - Delete the lower limit point 23 - Delete the 3rd limit 24 - Delete the 4th limit
0x08
Reset to factory
defaults
None
2 - RS485 control instructions