57(61)
Red alarm
light
Code
Possible reasons
Solutions
Remarks
[A.06]
Second carbon brush alarm
When carbon brush working
hours [F.17] gets to a certain
point (1000 hrs), [F.15] will raise
the alarm.
Please replace the
carbon brush and reset
carbon brush working
hour.
The alarm will last for 5
minutes. The machine
will repeat the alarm
every 15 minutes until
you reset carbon brush
working hour.
[A.07]
Third carbon brush alarm
When carbon brush working
hours [F.17] gets to a certain
point (1100 hrs), [F.16] will raise
the alarm.
Please replace the
carbon brush and reset
carbon brush working
hour.
The machine won't stop
the alarm until carbon
brush working hour is
reset.
[A.08]
Data can not be stored into
EEPROM.
Please contact our
company to replace the
PCB.
--Denotes the light is off, *Stands for flash of the light.