27(33)
21
Screen cleaning setting time
before suction
R/W
0
0
99
S
22
Screen cleaning setting time
after suction
R/W
5
0
99
S
23
Discharge checking time
R/W
10
5
99
S
24
Material shortage counting
alarm
R/W
3
1
9
times
25
Material shortage counting
stop alarm
R/W
3
Mat.
shorta
ge
countin
99
times
26
Standby time after motor
running
R/W
20
0
99
S
27
Buzzer alarm type
R/W
1
0
2
/
29
Motor working time record
R/W
0
0
999
10h
30
Full mat. detecting time
R/W
3
1
9
S
31
Mat. shortage detecting time
R/W
3
1
9
S
32
Mat. shut-off time
R/W
0
0
100
S
34
Motor delay stop time
R/W
0
0
999
S
35
Accumulating times of mixing
actions
R
0
0
0x03
set value
times
36
Accumulating times of
screen cleaning actions
R
0
0
0x04 set
value
times
37
Accumulating times of
material shortage alarm
R
0
0
99
times
38
Startup & shutdown control
W
0
startup
1 shutdown
/
39
Current action
R
/
/
bit 0 startup
0
1
bit 1 standby
0
1
bit 2 cleaning the filter screen
0
1
bit 3 wait for motor stopping
0
1
bit 4 absorb the material
0
1
bit 5 absorb the
masterbatch material
(mixing)
0
1
bit 6 wait for material
discharge
0
1
bit 7 wait for circulating
suction
0
1
Bit 8 ~bit 15 undefined
40
real-time information
R
/
/
41
Input and output state
R
/
/
bit 0 shortage input signal
0 full
mat.
1 mat.
shortage
bit 1 filter blocking input
signal
0 no
blockin
1 blocking
bit 2 suction output
0 no
output
1 output
bit 3 vacuum breaking output
0 no
output
1 output
bit 4 mixing output
0 no
output
1 output
Summary of Contents for SAL-10HP-UG
Page 1: ...SAL UG Separate vacuum Hopper Loader Date Sep 2020 Version Ver C English ...
Page 2: ......
Page 5: ...5 33 ...