14(33)
hopper are discharged into the hopper (12) via the material input pipe (12) due to
air pressure difference. After the suction is completed, the materials will drop due
to the gravity. If there
’
s no material sucked or shortage happens three times, the
alarm light (9) on the control box (10) will light up to alarm. During the blower
’
s (2)
suction process, the air in the pipe enters the filter (7) through the recycler to
remove the dust adhereded on the filter. When the blower finishes the suction
process, the vacuum breaking valve (3) between the blower and the filter will
produce the anti-impact air flow to blow away the dust adhereded on the filter to
the dust collection bin (5).
Summary of Contents for SAL-10HP-UG
Page 1: ...SAL UG Separate vacuum Hopper Loader Date Sep 2020 Version Ver C English ...
Page 2: ......
Page 5: ...5 33 ...