22(33)
4.2.2 Communication Parameter Setting
Press
key and
key together for 3 secs. to enter parameter setting screen.
Code
Functional Description
Parameters
Preset
value
Range
F.30
Comm. address
1
1-99
F.31
Baud rate
0---19200 1---9600 2---4800
1
0-2
F.32
Odd-even check
0---No test 1---
Odd parity 2--- Even parity
0
0-2
4.3 Alarm Procedure
Mixer controller, alarm state and troubling method.
Panel
Code
Alarm Reasons
Processing Mode
[A.01]
Shortage alarm [F.10]
1. The set suction time is too short.
2. The materials can
’
t be absorbed.
3. Suction pipeline is blocked.
4. Suction pipeline is too
small.
1) Add materials
2) Increase suction time
3) Shut down and check the pipe line.
When it sucks the materials again, the alarm will
dismiss or the ENT key on the panel can also be
cancelled or turn on the power again.
[A.03]
Filter warning
Filter screen blocking
1).Shut down and clean the filter screen.
Or replace filter screen.
The alarm will dismiss when turn on/off the power
again or it can be cancelled by clicking the ENT
key on the panel.
[A.04]
Shortage shutdown alarm [F.11]
When material shortage alarm
occurs, the shutdown alarm will
sound after shortage alarm
restarted for a certain number of
times.
Please refer to [A.01] processing method or
modify the value of [F.10] value.
Click the ENT key on the panel can cancel the
alarm or turn on the power again to start the
machine.
Please install panel setting to modify the set value.
4.4 Operaton Procedure Description