(4) Clean/Change Fuel Strainer
Clean
1
st
50 hours and Every 100 hours afterwards
Replace
Every 400 hours
①
Turn the fuel lever to [CLOSE].
②
Unscrew the retainer ring
counterclockwise, and remove the
cup and the filter element.
③
Discard any dust or water inside
the cup, and clean the filter
element by blowing compressed air,
or replace if necessary.
④
Reassemble it back.
<Caution>
Be sure to check for any contaminants on the seal, whenever reinstalling the
cup.
Turn the fuel lever to [OPEN] after assembling, and check for any leak. Having
confirmed no leak without fail, turn the fuel lever to [CLOSE].
Element Part No.
:
16271-43561 (Kubota)
(5) Drain Water from Fuel Tank
Drain Water
Every 200 hours
①
Unscrew the fuel drain plug.
②
Reinstall the drain plug, after draining
water completely
<Caution>
Change the seal, whenever drain water.
Seal Part No.
:
6C090-58961 (Kubota)
After reinstalling the fuel drain plug tightly,
keep the engine drive for a while to check no
fuel leakage and then stop the engine.
(6) Changing Coolant/Water
Replace
Every 2 years or 2000 hours
(Total Coolant/Water Capacity: about 3 L, including sub tank cap. 0.6 L)
①
Open the top plate.
②
Remove the radiator cap.
③
Loosen the water drain plug.
④
After draining all the water,
reinstall the water drain plug.
FUEL LEVER
CLOSE
OPEN
RETAINER
RING
FUEL DRAIN PLUG
TOP PLATE
WATER INLET
RADIATOR
CAP
COOLANT SUB TANK
WATER DRAIN PLUG