- 25 -
Checking Time
Checking Items
Startup
Check
At
50hrs
Every
100
hrs
Every
200
hrs
Every
400
hrs
Every
1000
hrs
Every
2000
hrs
13 Adjust V-Belt Tension
1
st
●
2
nd
or
after
●
14 Change V-Belt
●
or
2
years
15 Clean Radiator Fin
●
16 Clean Radiator (inside)
●
17
Change Fuel Hose,
Oil Hose,
Vibration-Absorbing Rubber
●
or
2
years
18
Adjust Engine Valve
Clearance
●
Adjust
●
Plane
19
Check/Adjust Injection
Nozzle
●
20
Check/Adjust Injection
Pump
●
(1) Oil Change
①
Remove the oil plug.
②
Loosen the oil drain plug and
allow the oil to drain fully.
③
Reinstall the oil drain plug.
④
Checking the oil level by the oil
level gauge, add oil into the oil
filler to fill up to the max level
(Approx. 3.8L).
④
Reinstall the oil plug hand tight.
<Caution>
Refer to
『
6-1. Checking Engine Oil
』
to select engine oil.
Change the seal, whenever changing oil.
Seal No.
:
6C090-58961 (Kubota)
After reinstalling the oil drain plug tightly, keep the engine drive for a while to
check no engine oil leakage and then stop the engine.
First Time
50 hour mark
2
nd
or after
Every 100 hours
OIL
GAUGE
OIL DRAIN PLUG
OIL PLUG
OIL INLET