44
(1) Storage Procedures
Perform the following maintenance procedures before storing this generator if it is not going to
be used for two months or more.
Remove the battery. (Refer to section “
8-7. Checking the Battery
”.)
Replace the engine oil.
(Refer to section “
10. Inspection/Maintenance (1) Engine Oil Replacement
”.)
Drain the fuel from the fuel tank and filter.
(Refer to section “
10. Inspection/Maintenance (4) Draining Water from the Fuel Filter
(Main and Pre-Filters)
. ”)
(Refer to section “
10. Inspection/Maintenance (7) Draining Water from the Fuel
Tank
”.)
Clean up and inspect inside of the spill containment.
(Refer to section “
10. Inspection/Maintenance (9) Flushing Liquid in Spill
Containment
”.)
Store in a secured location.
Clean up all generator components, and store in a dry and dust-free location. Also cover
when storing so that rain cannot enter through the suction or exhaust ports.
< Note >
Maintain fluid of the removed battery to the appropriate level and recharge every month.
WARNING : INJURY
Always turn t
he power switch to the OFF position and stop the engine, then close
and lock OPERATION PANEL DOOR before checking or maintaining the engine or
any equipment.
CAUTION : FIRE
Always be sure to wipe up any spilled fuel or oil.
Allow the generator to cool before covering with the protective cover.
CAUTION : BURNS
Do not touch the engine and surrounding components immediately after stopping the
engine as they are still extremely hot.