41
(11) Spill Containment Cleaning/Inspection
WARNING : INJURY
Do not attempt to lift the equipment with any additional weight such as optional
fuel tanks or trailers.
No persons should ever be under a lifted generator at all time.
CAUTION : INJURY
Always be sure to use lifting hooks when lifting up the generator, and raise it
slowly at a completely vertical angle.
Personnel performing lifting work must wear protective gear such as helmets,
safety shoes and gloves.
Do not move the generator during operation.
Clean
Every 500 hours
Separate the spill containment from this generator to clean and inspect the spill containment.
Spill Containment Separate/Reassemble
Turn the 3way fuel valve lever to the “A” side.
Remove the wiring connector.
Remove the fuel hoses (supply and return sides).
Remove the four spill containment fixing bolts (M12, 4 pieces).
< Note >
When removing the fuel hoses, hold the union joint fixed using a spanner or similar tool.
Prepare a container to receive the fuel remaining in the fuel piping that will flow out of the removed
fuel piping.
Lift the generator, separate the spill containment and set the generator on a flat surface.
After cleaning and inspecting the inside of the spill containment, reassemble the spill
container with this generator by performing the above procedures in the reverse order.
Reassemble the fuel piping and wiring connector to
their original positions.
Turn the 3way fuel valve lever to the “B” side.
< Note >
After reassembling, bleed air from the fuel system.
(Refer to section “9-3. Procedures during Operation”.)
After reassembling, check that there is no fuel leakage.
Spill Containment Cleaning/Inspection
Use a high-pressure cleaner or similar equipment to clean the inside of the spill
containment.
Remove the drain plug (R1”) to drain the cleaning water.
Check that there no rust has developed inside of the spill containment. If rust has
developed, remove the rust and clean again.
Tentatively, apply sealant coating to the plug (R1”) or wrap it in seal tape and reinsert it.
Allow water to accumulate and check that the spill containment has no internal leakage.
1
2
3
4
5
6
7
8
1
2
3
4
5
Position B
Position B
Position A
Position A