14. Characteristics
14-1. Rated current and heat value
By conducting current to the thyristor, voltage (0.9
-
1.3 V) is gererated between terninals. Voltage between terminals and accumulation of current (W)
turn into Joule heat, resulting in rise in temperature of the thyristor device. Take radiation and ventilation into account.
Internal heat value
Rated
current
20A 30A 45A 60A 80A 100A
Heat
value
22W 36W 47W 65W 77W 96W
14-2. Ambient temperature, elevation and load current
Ambient temperature (
℃
)
Load
current
(%)
Ambient temperature /
load current characteristics
-10
0
50 55
100
90
Elevation (m)
Load
current
(%)
Elevation / load current characteristics
0
2000
100
80
500
14-3. Control type and output waveform
The device includes phase control and cycle calculation zero voltage switching control types. Be sure to specify which type you require when ordering.
The customer cannot change control type.
A comparison of features is provided below.
Phase control
Cycle calculation zero voltage switching control
Output
Control type
Noise
generation
Output
0%
30%
50%
70%
100%
Large
Continuous
Small
Intermittent
Rated current of the device assumes an environment where ambient temperature does not rise above 55°C. If ambient temperature exceeds
50°C, reduce load current as shown in the following figure.