Dobot M1 User Guide
7
Maintenance
Issue V1.0.4 (2018-01-31)
User Guide
Copyright © Yuejiang Technology Co., Ltd
94
Item
Operating state
Inspection point
Inspection period
Solution
Bolt, screw
OFF
Check
whether the
screws
and
bolts around
each joint of
robotic
arm
are loose
Check
whether
the
screws
and
bolts of motor
and
reducer
are loose
12 months
If
that
happens,
please tighten them
Enabling
Robotic
arm
ON
Check whether each
arm can be moved
by hand in the open-
loop state
12 months
If
that
happens,
please
contact
technical
support
engineer
Cleaning Maintenance
The cleaning period depends on the operating environment and frequency, please decide the
cleaning period based on site requirements.
Item
Operating state
Cleaning period
Solution
Robotic arm
OFF
1 month
Please clean the surface
with clean cloth
Wind tunnel
OFF
2 weeks
Please
clean
the
impurities stored in the
wind tunnel with air gun
or clean cloth
Screw rod of Z-axis
OFF
12 months
Please add lubricating oil
or grease. For details,
Guide rail of Z-axis
OFF
2 weeks
Please add lubricating oil
or grease. For details,
please see
Common disinfectant, cleaning liquid can be used for cleaning robotic arm. Please do not use